Installation Guide
5. Installation
5.1 Ultrastar Data60 Installation Overview
5.1
Ultrastar Data60 Installation Overview
Procedure Info
Required Tools
Required Parts
# of People
Required
Time
Required
•
Long T15 Torx Screwdriver
•
# 2 Philips Screwdriver
•
Long T10 Torx Screwdriver
•
Cable Ties (for configurations
with greater than 10 total
cables)
•
Tape Measure
•
Level
•
M5 x 12mm T15 Flat Head Torx
screws
•
M5 x 12mm Phillips Pan Head
screws (to secure top cover)
•
Included Washers
•
Low-Profile M4 x 3.2mm Philips
screws (included with rail
assembly)
•
M3 x 8mm T10 Torx screws
•
10 M5 cage nuts
•
CMA Crossbar
•
Cable Tray (optional)
•
Optional (if using CMA Tray):
M3 x 8mm T10 Torx screws
•
Zip Tie (from CMA box)
3 Total (2 for
Team Lifting
Purposes and
1 to Guide and
Spot)
45 min.
Torque Specifications for Screws
Screw Type
Torque Value
M5 x 12mm T15 Flat Head Torx
screws
3.38-3.61 Nm / 30-32 in-lbf
M5 x 12mm Phillips Pan Head screws 3.38-3.61 Nm / 30-32 in-lbf
Low-Profile M4 x 3.2mm Philips
screws
.90-1.12 Nm / 8-10 in-lbf
M3 x 8mm T10 Torx screws
.33-.56 Nm / 3-5 in-lbf
Captive M5 Torx chassis cover thumb
screws
3.38-3.61 Nm / 30-32 in-lbf
5.2
Ultrastar Data60 Installation Procedure
39