Installation Guide
1. Overview
1.3 Ultrastar Data60 Specification Summary
Figure 4:
Component Layout
1.3
Ultrastar Data60 Specification Summary
Table 2:
Environmental Specification Summary
Specification
Non-Operational
Operational
Temperature
-40°C to 70°C
5°C to 35°C
Temperature Gradient
30°C / Hr
20°C per hour maximum
Temperature De-rating
1°C per 300m above 3000m
1°C per 300m above 900m
Relative Humidity
8-90% Non-Condensing
8-90% Non-Condensing
Relative Humidity Gradient
30% per hour maximum
30% per hour maximum
Altitude
-300m to 12,000m /
-984 ft. to 39,370 ft
-300m to 3048m /
-984 ft. to 10,000 ft.
Table 3:
Electrical Specifications
Specification
Value
Max Power Consumption
~1250W
Typical Power Consumption
~1000W
Input Voltage
200 - 240 VAC
PSU Connector Type
C14
PSU Efficiency
80 PLUS Platinum
* Max and typical power consumption values represent the output power to the system. Input power will vary depending
on the PSU efficiency and load sharing between PSUs.