5.2. Type Tests and Environmental Conditions
Environmental
phenomena
Basic
standard
Description
Test levels
ESD
EN 61000-4-2
Enclosure
Contact: ±6 kV
Air: ±8 kV
Fast transients
EN 61000-4-4
Power port
± 2 kV
I/O ports
Earth port
Surge 1.2/50 µs
EN 61000-4-5
Power port
LV and MV models:
L-E: ± 1 kV, 12
Ω
, 9 µF
L-E: ± 2 kV, 42
Ω
, 0,5 µF
L-L: ± 0,5 kV, 2
Ω
, 18 µF
L-L: ± 1 kV, 42
Ω
, 0,5 µF
HV models:
L-E: ± 2 kV, 12
Ω
, 9 µF
L-L: ± 1 kV, 2
Ω
, 18 µF
I/O port
L-E, L-L: ± 2 kV, 42
Ω
, 0.5 µF
Ethernet ports
L-E: ± 2 kV, 2
Ω
direct on shield
Power frequency
magnetic field
EN 61000-4-8
Enclosure
HV models:
100 A/m, cont.
1000 A/m, 3 s
Voltage dips and
interruptions
EN 61000-4-11
AC power port
HV models:
0% U
T
, 1 cycle
0%,U
T
, 250/300 cycles at 50/60 Hz
40% U
T
,10/12 cycles at 50/60 Hz
Pulsed magnetic field
EN 61000-4-9
Enclosure
300 A/m
Radiated RF
immunity
EN 61000-4-3
Enclosure
20 V/m at (80 MHz to 2 GHz)
10 V/m at (2-6 GHz)
1 kHz sine, 80% AM
Conducted RF
immunity
EN 61000-4-6
Power port
10 V, 80% AM, 1 kHz; (0.15-80) MHz
Ethernet ports
I/O ports
Earth port
Radiated RF emission
CISPR 16-2-3
Enclosure
LV and MV models: Class B
HV models: Class A
(30-6000 MHz)
ANSI C63.4
LV and MV models: Class B
HV models: Class A
(FCC Part 15 B, 30 MHz -25.5 GHz)
Conducted RF
emission
CISPR 16-2-1
Power port
LV and MV models: Class B
HV models: Class A
ANSI C63.4
LV and MV models: Class B
HV models: Class A
24