4. Installation
4.1. Mounting
RedFox is designed for installation in 19" rack solutions according to ETSI standard, with a
shallow depth of 240 millimetres. It can also be wall mounted as an installation option.
4.1.1. Rack Mounting
The product can be mounted in all directions inside a 19" apparatus cabinet. Use supplied
M6x25 (Philips no. 3) or 1/4x1" screws.
Digital in+
NO
C
NC
I/O
2
1
CONSOLE
ON
DC1
DC2
FRNT
RSTP/USR1
USR2
SD
POWER
+DC1
COM
4
3
6
5
8
7
9
12
11
14
13
16
15
18
17
20
19
22
21
24
23
26
25
28
27
+DC2
COM
Status
10
24 - 48 VDC
Figure 10. Rack mounted product
4.1.2. Wall Mounting
The product can be wall mounted in all directions. Use maximum 6.4 mm or 1/4" screws.
Digital in+
NO
C
NC
I/O
2
1
CONSOLE
ON
DC1
DC2
FRNT
RSTP/USR1
USR2
SD
POWER
+DC1
COM
4
3
6
5
8
7
9
12
11
14
13
16
15
18
17
20
19
22
21
24
23
26
25
28
27
+DC2
COM
Status
10
24 - 48 VDC
Figure 11. Wall mounted product
4.2. Earth Connection
For correct function, the earth connection needs to be properly connected to a solid
ground. See the figure below. Torx: T25. Torque: 3.2 Nm.
AC/DC
1
POWER 110-240 VAC / VDC
N (-)
L (+)
AC/DC1
AC/DC2
FRNT
RSTP/USR1
USR2
CONSOLE
ON
3
2
1
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
SD
Status
Digital in
I/O
NO C NC
DI+
DI-
Figure 12. Earth connection
4.3. Cooling
This product relies on convection cooling. To avoid obstruction of the airflow around the
product, follow the spacing recommendations.
18
RedFox 5528 Series