Environmental
phenomena
Basic
standard
Description
Test levels
Temperatures
EN 60068-2-1
EN 60068-2-2
Operational
For LV and MV models: -40 to +74°C (-40
to +165°F)
For HV models: -40 to +70°C (-40 to
+158°F)
Storage and
transport
-50 to +85°C (-58 to +185°F)
Humidity
EN 60068-2-30
Operational
5-95% relative humidity
Storage and
transport
Corrosive gases
a
IEC
60068-2-60
Operating
Method 3, 21 days
b
Altitude
Operational
2000 m/70 kPa
MTBF hours
MIL-HDBK
217F
RedFox-5528-(E-)F4G-T24G-MV: 381,000
RedFox-5528-(E-)F4G-T24G-LV: 371,000
RedFox-5528-(E-)F4G-T24G-HV: 316,000
RedFox-5528-(E-)F16G-T12G-MV:
397,000
RedFox-5528-(E-)F16G-T12G-LV: 386,000
RedFox-5528-(E-)F16G-T12G-HV: 353,000
RedFox-5528-(E-)T28G-MV: 366,000
RedFox-5528-(E-)T28G-LV: 356,000
RedFox-5528-(E-)T28G-HV: 303,000
Telcordia
RedFox-5528-(E-)F4G-T24G-MV: 667,000
RedFox-5528-(E-)F4G-T24G-LV: 643,000
RedFox-5528-(E-)F4G-T24G-HV: 678,000
RedFox-5528-(E-)F16G-T12G-MV:
735,000
RedFox-5528-(E-)F16G-T12G-LV: 706,000
RedFox-5528-(E-)F16G-T12G-HV: 710,000
RedFox-5528-(E-)T28G-MV: 643,000
RedFox-5528-(E-)(E-)T28G-LV: 620,000
RedFox-5528-(E-)T28G-HV: 653,000
Vibration
IEC 60068-2-6
(sine)
Operational
2 g rms 5-500 Hz, 5 sweeps
IEC
60068-2-64
(random)
Operational,
endurance test
12 dB/octave, 2-13.2 Hz, 0.011 g
2
/Hz,
13.2-100 Hz, 1.0 grms, 150 minutes per
axis
5-2000 Hz, rms 2.3 m/s
2
,1.5h
Shock
IEC
60068-2-27
Operational
30 g, 11 ms
Enclosure
EN 60950-1
Aluminum
Fire enclosure
Weight
3.8 kg
Degree of protection
EN 60529
Enclosure
IP40
26