47
925.476.4 - EN
INSTRUCTIONS PERTAINING TO THE INSTALLER
20. PARAMETERS SETTING
To set the boiler parameters press the
R
and
-
buttons together for at least 6 seconds. When the function is activated,
the display shows “
F01
” alternated with the value of the parameter.
Description of parameter
Default value
F01
Type of gas boiler
10
= sealed chamber
10
F02
Type of gas
00
= natural (metane) -
01
= LPG
00 o 01
F03
Hydraulic system
00
= instantaneous appliance
00
F04
Programmable relay 1 setting
2 = zone system
(See SERVICE Instructions)
02
F05
Programmable relay 2 setting
13
= “cool” function for external air-conditio-
ning system (See SERVICE Instructions)
04
F06
External sensor programmable input setting
(See SERVICE Instructions)
00
F07...F12
Manufacturer information
00
F13
CH max. heating output
(0-100%)
100
F14
D.H.W. max. heating output
(0-100%)
100
F15
CH min. heating output
(0-100%)
00
F16
Maximum temperature setpoint setting
00
= 85°C -
01
= 45°C
00
F17
PUMP OVERRUN TIME
(
01-240 minutes
)
03
F18
Minimum burner pause in central heating
mode -
00=10 seconds
03
F19
Manufacturer information
07
F20
Manufacturer information
--
F21...F22
Manufacturer information
00
F23
Maximum D.H.W. setpoint
60
F24
Manufacturer information
35
F25
Lack of water safety device
00
F26...F29
Manufacturer information
(read-only parameters)
--
F30
Manufacturer information
10
F31
Manufacturer information
30
F34...F41
Diagnostics (See SERVICE Instructions)
--
Final
parameter
Calibration function activation
(See SERVICE Instructions)
00
WARNING:
do not modify the values of the “manufacture information” parameters.
Parameters setting
• Press
+/-
buttons for scrolling parameters;
• Press
+/-
buttons to change the single parameter value;
• Press the
P
button to save changes, the display shows “
MEM
”;
• Press the
button to leave the function without saving, the
display shows “
ESC
”;
0801_0203 / CG_2017
Summary of Contents for star master 240 Fi
Page 83: ...83 925 476 4 RU 3 2 2 1 25 3 4 0801_0201 CG_2015...
Page 84: ...84 925 476 4 RU 4 1 C C ECO COMFORT ECO P eco COMFORT a PM12 0 20 3 2 3 1 0603_1301 2 4 2...
Page 85: ...85 925 476 4 RU 5 OFF OFF 3 2 OFF 6 7 LPG 5 C 30 C 8 3 0 7 1 5 OFF 3 2 3 0503_2405...
Page 91: ...91 925 476 4 RU 9 9 0904_1501 9a 9b 0904_1508 0904_1509...
Page 104: ...104 925 476 4 RU 32 NTC C M N R G V B V CG_1741 0904_1507 26...
Page 106: ...106 925 476 4 RU...
Page 107: ...107 925 476 4 RU...