User manual - English
User-manual-CombiLine-W80-W120-W240-0299-2
Seite 65
7.4
Reservoir
1. Switch off the machine at the production switch (aus/off) and pull out the power plug.
2. Completely empty the storage container and remove the insert plates (double bottom).
3. Thoroughly rub all storage container walls with a cloth soaked in WESSAMAT special cleaner
so that all dirt and limescale residues are removed. Rub thoroughly with clear water to remove all
cleaner residues.
4. Rub the drain pipe with WESSAMAT special cleaner and rinse thoroughly. Make sure that the
drain is locked in accordance with hygiene regulations (see page 13, section 5.2, point 3)
5. After all cleaned parts have been cleaned with clear water, insert the base plates again.
6. Plug with power supply
For health reasons, it is advisable to remove the first ice production cycle from the storage
container after cleaning and not to consume it.