- 14 -
6.6 USE OF GAUGE ARM FOR ALU WHEEL
6.6.1 WITH PROGRAM “ADJUSTER” ENABLE
Extract the distance/diameter measuring gauge and position it according to point “B” of Fig. 8,
without coming back to rest position select the location where to place the external weight point
“C” of Fig. 8.
Putting back to rest position the measuring gauge , automatically the ALU program is settled as ALU
program 4
Closing the wheel cover run a measuring cycle.
At the end of the spin wheel cycle, apply counterweight as indicated on screen: manually at 6
o’clock for the internal weight and arm gauge for external weight. Apply the weight on the arm
gauge site and extract it till an acoustic and visual signal advise for correct position.
Just in case Alu program 5 (spring weight on internal side) needed , after measuring cycle
(according point “A” and point “C” on Fig 8 below) and choosing right program pressing
ALU
key
and
-
key. In this case internal side weight has to be applied at 12 o’clock.
ATTENTION:
The automatic selection on the ALU programs, will work only when the
option “CAL.AUTOMAT” is enable; with option “EASY mode” enable will be mandatory
choosing manually the right program.
Fig. 8 Selected point measurements.