Automatic sauna splash system, type Sauna Plus 8 Basic
Index: 02
Date modified: 22/02/2022
OI No.: BA DW 010-02 Sauna Plus 8 Basic EN.docx
Page 17 of 36
5
Commissioning
5.1
Commissioning – remarks
The tasks described here must only be performed by appropriately qualified personnel from a specialist
company. Alternatively, the work can be carried out by persons who have read and understood the entire
Operating Instructions. Prior to commissioning, the installed systems must be checked for proper instal-
lation and leaks.
Please use the commissioning protocol from Chapter 9.3 for commissioning.
The device comes loaded with ex works settings. During the commissioning, adjust the control parameters
to the desired operating mode and enter them in the operation data sheet in Chapter 9.4.
5.2
Commissioning works
Filling and starting the automatic sauna splash system
1.
Please ensure that the device has been correctly installed and connected.
2.
Unscrew the cover of the fragrance delivery container and drill a hole with a diameter of 7 mm in
the cover. Screw the cover back on and place the delivery container on the console of the auto-
matic sauna splash system.
3.
Secure the fragrance container with the Velcro tape.
CAUTION!
The console is designed for loads up to 5 kg. If this load is exceeded, place the fragrance
containers on a separate shelf.
Most fragrances are highly flammable!
4.
Connect the fragrance container to the fragrance pump. Push the suction hose so far into the con-
tainer that the end of the suction hose comes into contact with the container base.
Insert the roller carrier at the fragrance pump
1.
Remove the clipped-in, transparent pump cover and the safety disc (32). Pull the hose bracket (33)
out of the guide in the housing. (During initial commissioning, the parts are not installed, but can be
found in the accessory bag)
Key
31.
Transparent pump cover (not shown)
32.
Safety disc
33.
Hose bracket with dosing hose made of Viton (hose kit)
34.
Roller carrier (not visible)
35.
Pump casing
41.
Suction connection
42.
Pressure connection
Figure 13, Peristaltic pump
32
35
34
33
41
42