GRANUDOS 45/100 PLUS V70 Touch
Index: 03
Change date: 25.04.2018
Operating instructions no.: BA SW 001-03 Granudos 45-100 PL V70T.docx
Page 38 of 92
Proceed as follows:
1.
Push the dust protection pipe (11) downwards.
2.
To exchange the drum, loosen the latch (9) of the drum holder and move the
turning mechanism with the empty drum from the dosing position upwards in
a clockwise direction; put one finger onto the dosing pipe so that no granulate
can fall out. Lock the turning mechanism. Point 2 is omitted during com-
missioning.
3.
Release the safety belt (3) and the fastening straps (2). Take the empty drum
from the turning mechanism. Unscrew the dosing hopper by turning it anti-
clockwise and place it next to the GRANUDOS PLUS. Point 3 is omitted
during commissioning.
4.
Remove the lid of the new drum and remove any pouring cup.
5.
Place the dosing hopper onto the drum and screw it tight, ensuring that the
grip recesses of the drum are at the sides and the control cable is on the right
side.
ATTENTION !
Care must be taken that the dosing hopper correctly fits the threads
of the drum, does not jam, and is properly connected after
tightening.
6.
Ensure that the new drum placed onto the turning mechanism touches the
back rails and the bottom spacer and that the holding rod interconnects with
the cross ribs of the drum.
7.
Then tighten the fastening straps
around the drum and close the
clamping lever. The clamping
lever must close tightly, but don't
use considerable force to turn
the clamping lever. The length of
the clamp band must be set
appropriately at the screw-type
ends.
8.
Insert the security pins into the
clamping lever!
9.
Pull the carrier belt (101) of the
safety belt from the back over
the heating pipe, so that the
clamping lock (103) of the fastener hangs in front of the hopper. Connect the
clamping lever (104) of the tension belt (106) to the clamping lock (103),
tighten the belt, and secure it with the securing pin. Adapt the length of the
adjustable belt (102) when the tension belt is not tight. Insert the security pin
(105)!
ATTENTION !
Care must be taken that all security pins are inserted!
10.
Unlock the drum holder by turning the spring lever (9) upwards. Hold the
dosing pipe closed with one finger and turn the drum slowly and anti-clockwise
Figure 28, Dosing head
101
102
103
104
105
106