RS232 Hi Power Data Sheet P.11 

 

Example:

  when  GID=1234  and  transmitted  side  which  UID=0A  send  data  to 

receive  side  which  UID=2A,  GID=0000.  But  equipment  which  UID=2A  can’t 

receive  any  data,  only  GID=1234  can  receive  data  from  receive  side  which 

UID=2A.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Detect  interface  rate: 

please  switch  interface  rate  and  input  72bytes  of  0X8D 

when  you  can’t  make  sure  the  interface  rate.  Equipment  side  will  return  same 
0x8D, total are 72bytes when interface rate is correct.   

 

Address 

Read/Write 

Byte 

Default(Hex) 

Range(Hex) 

0x8D 

72 

8D8D8D

8D 

 

 

Cancel transfer station: 

input 72bytes of 0X8F for one time when you need to 

cancel transfer station. When receiver side returns same 0X8F, total are 72bytes, 

it is meaning you cancel preset transfer station. You need to collocate with 

point-to-point transmission format after you cancel transfer station so that you 

just can start to normal working. 

 

 

 

Address 

Read/Write 

Byte 

Default(Hex) 

Range(Hex) 

0x8F 

72 

8F8F8F

8F 

 

 

Preset  transfer  station: 

this  function  needs  to  preset  constant  path  of  data 

transmission  mode.  After  finish  preset,  every  data  doesn

’t  need  to  add  any 

command and path, but the data which you send every time must be less than 64 

bytes.  Equipment  will  automatically  transfer  and  send  data  according  to  preset 

path. Maximum transfer stations you can set are 10. Setting way is to add UID 

number  on  finial  receiver  side  behind the  command.  If  you  need  to  go  through 

transfer station, you need to insert UID number of path in the middle.

 

GID:1234

UID:2A

GID:1234

UID:0A

GID:0000

UID:2A

Transfer data=ABCDEF

Only GID=1234 Receive

Receive data=ABCDEF

Non receive data

Summary of Contents for RS232 Hi Power

Page 1: ...a Sheet P 1 WENSHING RS232 Hi Power Wireless RS232 High Power Transceiver 2W Instruction Manual Revision History Version Date Changes V1 02 Mar 2 2009 First Edition V1 03 May 23 2009 Second Edition V1...

Page 2: ...hannel Home Automation Standard Wireless RS232 Active RFID Base Station Transceiver Characteristic Parameter Min Type Max Unit Condition Operating Condition Operating Temperature Range 40 85 Operating...

Page 3: ...http www wenshing com tw http www rf net tw RS232 Hi Power Data Sheet P 3 Block Diagram View...

Page 4: ...http www wenshing com tw http www rf net tw RS232 Hi Power Data Sheet P 4 Accessory Antenna Standard Switching Adapter Standard Plug Option...

Page 5: ...e is 0x01 RS232 Modem 0x87 Set group ID 0x87 2 bytes 0x0000 FFFF Correct setting will return send value incorrect setting will have no back value 2 bytes setting default value is 0x0000 0x8D Detect in...

Page 6: ...1 transfer 1 receive 0x73 1 send 2 transfer and 1 receive Path order Preset set process of Point to Point Transmission mode When you use point to point transmission mode please set corresponding para...

Page 7: ...ta format which you send is 0x71039999 If you want to send data 9999 from equipment which UIP 01 through equipment which UID 03 to transfer to equipment which UID 04 data format which you send is 0x72...

Page 8: ...ress Read Write Byte Default 0x80 R TRW909V100 Set RF transmission rate we suggest you to collocate with interface rate as setting when you set wireless transmission rate Normal setting RF transmissio...

Page 9: ...et power consumption user can amend power consumption through command according to different application Available set rage is from 3mW to 2W and default value is 100mW Address Read Write Byte Default...

Page 10: ...520 0 Code 0x00 0x01 0x02 0x03 0x04 0x05 0x06 0x07 Set link mode RS232 Hi Power can collocate with RD 800HI and 3C message receive device User can amend the link mode through command according to the...

Page 11: ...ytes it is meaning you cancel preset transfer station You need to collocate with point to point transmission format after you cancel transfer station so that you just can start to normal working Addre...

Page 12: ...rom equipment which UID 01 to equipment which UID 04 Method 1 command is 0xC00304 when UID 01 UID 03 UID 04 Or command is 0xC00204 when UID 01 UID 02 UID 04 Method 2 command is 0xC0020304 when UID 01...

Page 13: ...http www wenshing com tw http www rf net tw RS232 Hi Power Data Sheet P 13 Or command is 0xC0030204 when UID 01 UID 03 UID 02 UID 04 GID D391 UID 02 GID D391 UID 01 GID D391 UID 04 GID D391 UID 03...

Reviews: