background image

 

http://www.wenshing.com.tw; http://www.rf.net.tw 

RS232 Hi Power Data Sheet P.2 

Key Feature 

  UHF Band Wireless Data Transceiver 

  Exclusive Hopping Technology 

  RF Output Power up to 2W 

  Sensitivity up to -118dBm 

  Voltage Supply from Switching Adapter 

  RS232 Interface 

  Transceiver Data Rate 1.6Kbps~128Kbps   

 

Application 

  Wireless Network 

  Multi-Channel Home Automation Standard 

  Wireless RS232 

  Active RFID Base Station Transceiver 

 

Characteristic 

Parameter 

Min 

Type 

Max 

Unit 

Condition 

Operating Condition 

Operating Temperature 

Range 

-40 

 

+85 

 

 

Operating Supply Voltage 

4.8 

5.5 

 

Current Consumption 

RX Mode 

 

 

40 

mA 

 

TX Mode 

 

 

1500 

mA 

2W Peak 

Sleep Mode 

 

 

23 

mA 

 

RF Characteristic 

Frequency Range 

902 

 

928 

MHz 

 

Data Rate 

1.6 

 

128 

Kbps 

GFSK 

TX Output Power 

33 

34 

dBm 

 

RX Sensitivity 

 

 

-118 

dBm 

 

Modulation 

 

GFSK 

 

 

 

Other 

ESD 

 

 

2000 

 

Interface Data Rate 

1.2 

 

115.2 

Kbps 

 

Dimension 

74.9 x 25.6 x 25.6 

mm 

 

Summary of Contents for RS232 Hi Power

Page 1: ...a Sheet P 1 WENSHING RS232 Hi Power Wireless RS232 High Power Transceiver 2W Instruction Manual Revision History Version Date Changes V1 02 Mar 2 2009 First Edition V1 03 May 23 2009 Second Edition V1...

Page 2: ...hannel Home Automation Standard Wireless RS232 Active RFID Base Station Transceiver Characteristic Parameter Min Type Max Unit Condition Operating Condition Operating Temperature Range 40 85 Operating...

Page 3: ...http www wenshing com tw http www rf net tw RS232 Hi Power Data Sheet P 3 Block Diagram View...

Page 4: ...http www wenshing com tw http www rf net tw RS232 Hi Power Data Sheet P 4 Accessory Antenna Standard Switching Adapter Standard Plug Option...

Page 5: ...e is 0x01 RS232 Modem 0x87 Set group ID 0x87 2 bytes 0x0000 FFFF Correct setting will return send value incorrect setting will have no back value 2 bytes setting default value is 0x0000 0x8D Detect in...

Page 6: ...1 transfer 1 receive 0x73 1 send 2 transfer and 1 receive Path order Preset set process of Point to Point Transmission mode When you use point to point transmission mode please set corresponding para...

Page 7: ...ta format which you send is 0x71039999 If you want to send data 9999 from equipment which UIP 01 through equipment which UID 03 to transfer to equipment which UID 04 data format which you send is 0x72...

Page 8: ...ress Read Write Byte Default 0x80 R TRW909V100 Set RF transmission rate we suggest you to collocate with interface rate as setting when you set wireless transmission rate Normal setting RF transmissio...

Page 9: ...et power consumption user can amend power consumption through command according to different application Available set rage is from 3mW to 2W and default value is 100mW Address Read Write Byte Default...

Page 10: ...520 0 Code 0x00 0x01 0x02 0x03 0x04 0x05 0x06 0x07 Set link mode RS232 Hi Power can collocate with RD 800HI and 3C message receive device User can amend the link mode through command according to the...

Page 11: ...ytes it is meaning you cancel preset transfer station You need to collocate with point to point transmission format after you cancel transfer station so that you just can start to normal working Addre...

Page 12: ...rom equipment which UID 01 to equipment which UID 04 Method 1 command is 0xC00304 when UID 01 UID 03 UID 04 Or command is 0xC00204 when UID 01 UID 02 UID 04 Method 2 command is 0xC0020304 when UID 01...

Page 13: ...http www wenshing com tw http www rf net tw RS232 Hi Power Data Sheet P 13 Or command is 0xC0030204 when UID 01 UID 03 UID 02 UID 04 GID D391 UID 02 GID D391 UID 01 GID D391 UID 04 GID D391 UID 03...

Reviews: