56
EN
12.2 System Components
12.2.1 Relay Unit Type 2/Type 4 SG4-00VA000R2
Output
2 sets of 2 NO contacts
Response time
8 ms
Contact load
Max. switching capacity
1500 VA/AC
Voltage/Current/
Switching Cycles B10
d
250 V AC / 4 A / 180 000
24 V DC / 4 A / 1 400 000
24 V DC / 2 A / 3 000 000
Mechanical Service Life
10 000 000 Cycles
Recommended spark arrestor
110 to 230 V load circuit: R = 220 W, C = 0.22 µF
24 to 48 V load circuit: R = 22 W, C = 0.22 µF
Dimensions
114.5 × 99 × 22,6
Conductor cross-section
0,2…2,5 mm²
Protection
IP20
Mounting
35 mm top-hat rail per EN 60715
Fuse Required
4 A delay fuse
Contact Resistance
≤
100 mW / 1 A / 24 V DC
≤
20 W / 10 mA / 5 V DC
Minimum Load
> 50 mW
12.2.2 Adapter Box RS-232 to A485-232
Power supply
10…30 V, 2,4 W bei 24 V
Dimensions
35 × 65 × 50 mm
Protection
IP65
Mounting
35 mm top-hat rail per EN 60715
12.2.3 Laser Alignment Aid SZ0-LAH1
Voltage Supply
3 V (2 × 1,5 AA battery)
Type of light
Laser (red)
Laser Safety Class
2
12.2.4 Mounting Elements
BEF-SET-18
for T-Notch
BEF-SET-36
for mounting inside the Protection Housing