43
5.5.4 Coding
wenglor light curtains are coded at the factory in order to assure that any given emitter is only capable of influenc-
ing its own corresponding receiver. The coding of the light curtain can be changed during initial start-up. Coding is
initialized as follows:
Start
Blanking
Alignment-LED and
Failure-LED light up
continuously?
Adjust
Set the timing DIP switch
no
FE appears at the display
Press the enter button on the emitter for
approx. 10 s and then release
The pilot beam is transmitted
Align the pilot beam to the emitter
Improve
alignment
Reset the timing DIP switch
Press the enter button on the emitter
or interrupt supply power to the emitter
The receiver boots
DIP Switch Settings: Receiver
Serial Communication
Cascading
Timing
Restart Inhibit
8
7
6
5
4
3
2
1
ON OFF
Contactor Monitoring
Reduced Resolution
Fix Blanking
S1
Display at Receiver
or
FF: Emitter switched off
00: Emitter switched ont
In order to reset to standard encoding (default status), please proceed as follows:
Same procedure as above, but only press and hold the enter button on the emitter for a duration of 1 to 3 seconds.
The red error indicator must not light up while the enter button is being pressed and held. If the red error indicator
lights up, the enter button has been pressed and held too long.
Alternatively the following procedure can be used:
Safety Light Barriers-System
Type of coding
Emitter 1 / Receiver 1
Standard coding (Delivery status)
Emitter 2 / Receiver 2
Coding according to flow diagram chapter 5.5.4
Emitter 3 / Receiver 3
Standard coding (Delivery status)
Emitter 4 / Receiver 4
Coding according to flow diagram chapter 5.5.4
Emitter 5 / Receiver 5
Standard coding (Delivery status)