34
EN
Connector Pin Assignments for Safety Operation with Auto-Floating Blanking
Required system components:
1 × emitter, 1 × receiver
1 × connector cable for emitter
1 × connector cable for receiver
1 × Mutingmelder
From
to
Emitter Wiring
Pin 1
24 V DC
Supply Voltage 24 V DC
Pin 2
Unused
Pin 3
Ground (0 V)
Supply Voltage 0 V
Pin 4
Earth/shield
Operational earth
Receiver Wiring
Pin 1
Signal output
Muting indicator muting terminal
Pin 2
24 V DC
Supply Voltage 24 V DC
Pin 3
OSSD 1 output
PLC or relay
Pin 4
Acknowledge
free
Pin 5
Contactor monitor
free
Pin 6
OSSD 2 output
PLC or relay
Pin 7
Ground (0 V)
Supply Voltage 0 V
Pin 8
Earth/shield
Operational earth
The object may be moved in the auto-floating blanking operating mode. Important: A warning lamp must be
installed!
Warning lamp Wiring
GND
Ground (0 V)
Supply Voltage 0 V
24 V
24 V DC
Supply Voltage 24 V DC
Return
Signal return
Unused
Muting Signal
Receiver pin1, signal output
5.4.3.3 Calculating Safety Clearance
When calculating the safety clearance for the auto floating blanking mode, the same rules and requirements must
be observed as is also the case with the floating blanking mode (see section 5.4.2.3).