18
EN
5.2.2 Adjustment Procedure
Start
Set all DIP
switches to off
Align the light curtain
mechanically
Press and hold the
enter button on the
receiver for 1 s
Do the
blanking alignment
and failure LEDs
blink?
Degree of alignment
appears at the display
99 – very good
44 – not good
43 – beams masked
see table “Degree of alignment
against the distance between
transmitter and receiver”
Press and hold the
enter button on the
receiver for 1 s
The receiver boots
and activates the
outputs
The light curtain
is ready for operation
Display at Receiver
Serial Communication
Cascading
Timing
Restart Inhibit
8
7
6
5
4
3
2
1
ON OFF
Contactor Monitoring
Reduced Resolution
Fix Blanking
S1
Function Mode:
Safety Operation Mode
DIP Switch Settings: Receiver
yes
Improve
alignment
no
…
Distance transmitter – receiver
Without deflection mirror With 1 deflection mirror
With 2 deflection mirrors Degree of alignment
≤
3 m
≤
2,7 m
≤
2,4 m
96 imperatively necessary
3…7 m
(finger protection)
3…20 m
(hand protection)
2,7…6,3 m
(finger protection)
2,7…18 m
(hand protection)
2,4…5,6 m
(finger protection)
2,4…16 m
(hand protection)
96, 78, 68, 56 preferred
> 43 necessary
Tab.: Degree of alignment against the distance between transmitter and receiver
The following must be observed:
The safety field’s pilot beam may not be continuously interrupted.
The adjustment procedure must be repeated each time the device is remounted (e.g. change in
operating range).