36
wTeach2 Configuration Software
7.3 Events
Events are diagnostic information that is standardized by IO-Link and exchanged between the IO-Link master
and the device. The following events are supported:
Name
Event Code Type
Specification
Maintenance required – Cleaning
0x8C40
Notification
IO-Link
General malfunction – Unknown error
0x1000
Error
IO-Link
Short circuit – Check installation
0x7710
Error
IO-Link
Device temperature over-run – Clear source of
heat
0x4210
Warning
IO-Link
Device temperature under-run – Insulate device
0x4220
Warning
IO-Link
Temperature fault – Overload
0x4000
Error
IO-Link
Primary supply voltage under-run – Check toler-
ance
0x5111
Warning
IO-Link
Acceleration sensor
0x1801
Warning
wenglor-specific
8. wTeach2 Configuration Software
8.1 General
For information on installing and connecting the software and its structure, as well as information on the gen-
eral functions, see the wTeach operating instructions. They can be found online in the download area under
order number DNNF005.