27
Controller for Through Beam Sensors
7.2. Teaching In the Sensitivity
By means of the Teach-In procedure the ideal sensitivity of the Through Beam Sensors is adjusted. Three
Teach-In modes are available, each calculates the sensitivity in a different way.
• NORMAL TEACH
• MIN TEACH
• TEACH-IN in areas with high probability of contamination
7.2.1. NORMAL TEACH
Recognition of signal level differences of 50 %
• Turn the rotary selector switch
to position 2
• Do not position an object within the light beam
• Press the teach-in key
once
• Turn the rotary selector switch
to RUN
1×
No object, light beam is unobstructed
SA250-xxx EA250-xxx