Do not modify or dismantle all or part of the product.
respect the power supply voltages and the connection terminals.
ensure power supply is switched off whilst connecting product and turn on only once product is fully 
connected. Failure to do this may damage the product and invalidate the warranty
Do not stare at the lighting source directly. 
Follow advice below for installation to minimise operator exposure to the light source.

INSTALLATIoN GUIDANCE:

•  Forbid or limit the direct access to the lighting source (exposure into the radiation axis).
•  Establish a security perimeter to prevent the operators from approaching the lighting source beyond the recom-

mendations of the manufacturer.

•  If the workstation permits it, introduce a filter that will stop the lighting radiation under a fixed or adjustable 

frame between the source and the operator. When these measures cannot be implemented, supply the opera-
tors with glasses (class 4) or with a dedicated protective mask, that will stop the lighting radiation.

It is the responsibility of the persons installing this product to ensure that all means possible (such as those stated 
above) have been implemented to reduce exposure of the machine operators to the light emitted from this product.

MountIng acceSSory

  (oPtional)

Ref: ZMRX001

*Supplied

2x

 

screws

 

M5x10*

Summary of Contents for LMRX Series

Page 1: ...nimise photo biological risks including the nominal mini mum operating distance Please contact wenglorTPL through your usual representative for this information wenglorTPL recommends the use of protec...

Page 2: ...ghtening torque from 0 5 to 1 5 Nm We also recommend the use of a threadlocker not supplied to avoid any risk of loosening Dimensions RING Total length mm Width mm Height mm A B C LMRX1xx 193 136 11 L...

Page 3: ...P3 12 LED indicators Operating mode Strobe ELECTRICAL CONNECTION M12 5 male pins M12 8 male pins n Power supply n Strobe n Dimming n Sector control n Color control n Overdrive enabling n Lock Keypad...

Page 4: ...rs CW Keyboard deactivated Sector control via M12 8 pins 1 7 6 2 3 4 5 8 green yellow brown blue pink white red grey Remote control connection 1 2 4 3 1 Active overdrive connect to 24VDC 2 Change colo...

Page 5: ...tions as illustrated here For Dimming the Pin 5 should be connected to a voltage between 0V and 10V to ensure light output is correctly configured The M12 male connector 5 points is com pliant with th...

Page 6: ...quency 50 000 Hz D max 10 t max 2 ms max frequency 310 Hz D duty cycle t pulse duration CW continuous working D duty cycle t pulse duration P6 12 10 2 4 6 8 10 12 14 30 50 70 90 110 130 150 170 190 21...

Page 7: ...der PNP NPN strobe control On time t duty cycle D in CW Overdrive modes PNP NPN LED current Courant Led 2 ms max overdrive P7 12 Strobing the light via PNP or NPN behaviour If a trigger signal of more...

Page 8: ...PNP or NPN trigger signal should be enabled in addition to the Sector or Color control signal s Timing diagrams below illustrate rise fall and delay times If PNP and sectors are connected to 24V and...

Page 9: ...With 0V applied to the Dimming pin the product is at 100 of its lighting power With 10V applied it is reduced to 30 of lighting power operatingConditions 10 to 40 C 14 to 104 F 80 of humidity without...

Page 10: ...sh of Color and or Sector button s until desired configuration is selected Save settings push the 2 buttons together for 3 4 seconds Color selection Sector selection Sector configurations 1 2 4 3 1 2...

Page 11: ...axis Establish a security perimeter to prevent the operators from approaching the lighting source beyond the recom mendations of the manufacturer If the workstation permits it introduce a filter that...

Page 12: ...erature build up at the LED junction The junction temperature of the LED is directly correlated with the lifetime of the LED chip Maximum ambient air temperature maximum 40 C 104 F LEDs naturally lose...