VOLTAGE FREQUENCY TIME
KNOW YOUR INVERTER GENERATOR
CONTROL PANEL
1
3
4
5
6
7
8
10
11
13
14
16
1. Data Meter with Indicator Light
2. Overload Reset
If the overload light is ON, press this button to reset.
3. CO WATCHDOG Carbon Monoxide Monitor
Measures the accumulation of poisonous CO gas while
the generator is running. If the level of CO gas gets too
high, the CO Watchdog system will automatically shut
down the generator. See p. 23 for more information.
4. Eco-Mode Switch
Turn ON to increase fuel economy and runtime when the
load is below 2550W (75% load).
5. Parallel Connection Port
Connect two WEN inverter generators through a parallel
connection kit for a higher output.
6. DC 12V Cigarette-Lighter Style Receptacle
7. DC 5V USB Outlet
8. Grounding Nut
Ground generator to reduce risk of electric shock.
9. DC Circuit Breaker (10A)
10. AC 120V NEMA TT-30 Receptacle (28.3A)
11. AC Circuit Breaker for NEMA 5-20R (20A)
12. AC 120V NEMA 5-20 Duplex Receptacles (20A)
13. Manual Shutoff Button
Push down for 10 sec. to shutoff generator manually.
14. 3-in-1 Switch
Turn switch to start, run, and automatically shut off the
generator.
15. Engine Start Button
Turn switch to "Start" and press button to ignite the en-
gine.
16. Auto OFF / Fuel Shutoff
Automatically shuts off generator after fuel in the carbu-
retor is consumed.
11
2
9
15
12