background image

WEMPE ENI 

secondary clocks interface

Installation

1.1  Configuration

 

The Wempe Ethernet Slaveclock consists of two parts:  The mechanical clock and the electronic 
Ethernet Network Interface (ENI). The arms of the slave clock are self adjusting and pre setted 
already. Normally no further administration or commissioning is necessary. If other than the default pre 
settings are desired, the ENI can be administrated using the ENI web interface.  

Please use a browser to enter the web interface: 

http://ENI-IP-ADDRESS

 . Now you have access to all 

the adjustments. The standard login data you can find in the owners manual or ask your IT office.  

The manufacturer pre-set IP address is shown on the ENI's label.  (172.16.n.n / 255.255.0.0) 

Be sure to select the correct compatibility mode. Possible settings are: Master Clock 20100, 
20101 or 20102: 

Supported LAN parameters: IP address, subnet mask, gateway address, primary and secondary NTP 
server (not at ENI V1 legacy mode). 

The allocation of IP addresses is static by default. This can be changed to obtain addresses from a 
DHCP server. The DHCP query asks for addresses of NTP servers, too. If the DHCP server provides 
them, up to two addresses will be mentioned by the ENI configuration. 

1.2  Ethernet network connection 

The  ENI  is  designed  for  operation  via  a  PoE  switch.  This  means  that  the  power  supply  and  data 
communication  is  provided  by  the  same  device.  Alternatively,  24VDC  power  can  also  be  supplied  to 
the ENI via the terminal block.  

Attention: Do NOT connect at the same time Power over Ethernet 

AND the external 24 DC power supply. 

1.3  Setting up the Master Clock connection 

The network configuration depends on the type of time source / master clock. 

The first steps are common for all connection types: 

Open a web browser and navigate to the URL shown on the ENI's label as IP address.

Proceed to the Configuration page, give username and password (see chapter 3).

If desired, change the individual static IP address or enable the DHCP client and figure out the

P address the ENI obtained from the DHCP server.

Set a location name to identificate the ENI in the Master Clock database easily.

PoE-Switch 

ENI 

Master 

Clock 

Patch cable 

Patch cable 

Summary of Contents for 20804/IP

Page 1: ...d and glass frame Geh use Housing Messing hochglanz verchromt brass high gloss chrome plated Abmessungen mm Dimension mm 232 H he 65 232 height 65 Zifferblatt mm Dial mm Aluminium wei 230 aluminium wh...

Page 2: ...mmleiste Terminal block Ersatzteile spare parts TypE T Type IP Art No Beschreibung description ENI v3 WEMPE Ethernet Secondary clock interface Connector RJ45 Ethernet 10Base T IPv4 network cable twist...

Page 3: ...die Buchse am Zeiger etwas zusammengedr ckt werden Setzen Sie danach den Minutenzeiger auf die Minutenachse und ziehen Sie die Stiftschraube M2 der Buchse fest an Es ist darauf zu achten dass zwische...

Page 4: ...ghtly squeezed Then place the minute hand on the minute arbour and tighten the pin screw M2 of the liner Please pay attention that there is enough space between the hands To check this turn the minute...

Page 5: ...ce ENI Ethernet Secondary Clocks Interface Quick Start Guide valid for Hardware Rev 3 0 03 10 2016 Firmware V3 05 05 12 2016 V3 06 22 12 2016 Secondary Clock Ethernet Interface Compatible with Wempe M...

Page 6: ...tatic by default This can be changed to obtain addresses from a DHCP server The DHCP query asks for addresses of NTP servers too If the DHCP server provides them up to two addresses will be mentioned...

Page 7: ...to reconnect the web browser after a few seconds Further ENI configuration can be done on the Master Clock s web interface see it s manual Master Clock Rev Master Clock Software Version1 Select ENI V...

Page 8: ...subnet This option requires a working DHCP server on the same subnet that the ENI is connected to Set_MIN Force the network initialization to use the static IP address 172 16 0 100 which is the facto...

Page 9: ...ng off INIT Can t finish initialization most likely the device is damaged MAC No physical network connection LINK Network up but doesn t respond to IP requests CONN Network up but no IP address possib...

Page 10: ...one user name and one password There is no way to add or delete account names There is no limit in the count of failed logins due to wrong passwords To protect the web interface access against brute...

Page 11: ...s from PC to ENI and back The ping tool on the Tools page of the web interface see ENI user manual can assist Check any blocking features firewall etc at every routing device between ENI and PC Try us...

Page 12: ...2 to set the correct protocol version Check the IP addresses of ENI and masterclock are in the same IP subnet or VLAN The ping tool on the Tools page of the web interface see ENI user manual can assis...