background image

M508 p/n 2M-304456  Owners Manual WV

-2HG 

FEATURES & OPERATING CONTROLS (continued)

Fig. 2  Ventilator Section Controls & Indicator Lights

IL2603

VENTILATOR
POWER ON

CHECK FILTERS

REPLACE
PREFILTER

REPLACE
FILTER PACK

SERVICE
REQUIRED

4

Fig. 3  Griddle, Hotplate and Drawer Warmer Sections

IL2604

GRIDDLE
SECTION

COOKTOP

CONTROLS

HOTPLATE

SECTION

OPTIONAL

DRAWER WARMER

SECTION

Summary of Contents for WV-2HFG

Page 1: ...his appliance Additional manuals are available from your WELLS DEALER THIS MANUAL MUST BE READ AND UNDERSTOOD BY ALL PERSONS USING OR INSTALLING THIS APPLIANCE Contact your WELLS DEALER if you have any questions concerning installation operation or maintenance of this equipment 508 p n 2M 304456 Rev E M508 130125 OWNERS MANUAL WV2HG SERIES GRIDDLE HOTPLATE COOKTOP with UNIVERSAL HOOD MODELS WV2HFG...

Page 2: ...of loss or damage is signed by the delivery person 2 FILE CLAIM FOR DAMAGE IMMEDIATELY Regardless of the extent of the damage 3 CONCEALED LOSS OR DAMAGE if damage is unnoticed until the merchandise is unpacked notify the transportation company or carrier immediately and file CONCEALED DAMAGE claim with them This should be done within fifteen 15 days from the date the delivery was made to you Be su...

Page 3: ...a long economical service life This manual contains the information needed to properly install this appliance and to use and care for the appliance in a manner which will ensure its optimum performance TABLE OF CONTENTS SPECIFICATIONS INTRODUCTION 1 MODEL ROLL WARMER VOLTS 50 60 Hz 3ø AMPS 1ø AMPS WATTS DIMENSIONS POWER CORD L1 L2 L3 WV2HFG NO 208V 16 32 23 38 8 000 30 3 8 WIDE 240V 18 35 24 41 9 ...

Page 4: ...M508 p n 2M 304456 Owners Manual WV 2HG FEATURES OPERATING CONTROLS Fig 1 Ventilator Section Operating Features Controls 2 IL2602 ...

Page 5: ...Y Comprises the PRE FILTER FRAME and a replaceable PRE FILTER Stops larger particles of grease from reaching the FILTER PACK for reduced maintenance costs 19 HI EFFICIENCY CHARCOAL FILTER PACK Stops most grease and smoke particles Also assists in some cooking odor removal 22 GREASE DRIP TRAY Collects grease moisture dripping from grease baffle 16 28 VENTILATOR EXHAUST DUCT Exit point for ventilato...

Page 6: ... 2 Ventilator Section Controls Indicator Lights IL2603 VENTILATOR POWER ON CHECK FILTERS REPLACE PREFILTER REPLACE FILTER PACK SERVICE REQUIRED 4 Fig 3 Griddle Hotplate and Drawer Warmer Sections IL2604 GRIDDLE SECTION COOKTOP CONTROLS HOTPLATE SECTION OPTIONAL DRAWER WARMER SECTION ...

Page 7: ...IDDLE Removable for cleaning G 04 COOKING SURFACE Heated portion for cooking food G 05 WASTE TROUGH Scrape cooking waste to this area G 06 WASTE CHUTE Cooking waste moved into GREASE DRAWER thru this opening HOTPLATE SECTION H 01 TEMPERATURE CONTROLS Individual infinite switch control of the hotplate HEATING ELEMENTS H 02 POWER INDICATOR Glows anytime the TEMPERATURE CONTROL is in any position oth...

Page 8: ... supplied by user Disconnect this appliance from electrical power before performing any maintenance or servicing Any procedure which requires the use of tools must be performed by a qualified technician This appliance is not jet stream approved Do not direct water jet or steam jet at this appliance or at any control panel or wiring Do not splash or pour water on in or over any exposed element cont...

Page 9: ...e Wells replacement parts and filters call 314 678 6314 or your authorized Wells service agent Parts supplied by others will void your warranty and may not provide safe operation The technical content of this manual including any wiring diagrams schematics parts breakdown illustrations and or adjustment procedures is intended for use by qualified technical personnel This manual is considered to be...

Page 10: ... at hand and have someone available who is capable of replacing it Otherwise you may experience an extended down time with consequent associated loss of business The manufacturer assumes no liability for loss of business due to a system shutdown caused by a dirty pre filter and or filter pack i e red SERVICE REQUIRED light is on when the user fails to have the proper replacement pre filter and or ...

Page 11: ...stalled before operating the appliance 1 ea FIRE SUPPRESSION AGENT ANSULEX Low pH 1 5 GAL See Material Safety Data Sheet page 28 1 ea FIRE SUPPRESSION MEDIA TANK 1 ea FIRE SUPPRESSION TANK CHARGING CARTRIDGE 1 ea GREASE BAFFLE 1 ea FILTER PACK ASSEMBLY 1 ea PRE FILTER HOLDER with PRE FILTER 1 ea GREASE DRIP TRAY 1 ea GREASE DRAWER ASSY FOR GRIDDLE 2 ea 6 SIDE SPACERS 1 ea LITERATURE PACKAGE Additi...

Page 12: ...r wire rated for at least 90ºC NOTE Wire gauge insulation type and temperature rating as well as type size and construction of conduit must meet or exceed applicable specifications of local codes and of the National Electrical Code NOTE This appliance requires a NEMA 15 60R receptacle 3 This appliance must be connected to a suitable building ground The equipment ground connection is marked 4 The a...

Page 13: ...uzzer will sound continuously The fire suppression media will form an emulsion designed to both smother and cool the fire Call your Authorized Ansul Distributor immediately for service NOTE See page 24 for the Material Safety Data Sheet for the fire suppression agent 4 The MANUAL PULL STATION and any similar REMOTE MANUAL PULL STATION will activate the fire suppression system when the ring on the ...

Page 14: ...nd seat the assembly into the top indentation of the lower filter rail 3 GREASE BAFFLE If the GREASE BAFFLE is not in place the CHECK FILTERS indicator will glow To install the GREASE BAFFLE Slide the grease baffle up into the indentation of the upper filter rail then lower and seat it into the bottom indentation of the lower filter rail Pull toward you and downward to verify the GREASE BAFFLE is ...

Page 15: ...EASE DRIP TRAY on the hanger brackets directly below the grease baffle ROLL WARMER DRAWER INSTALLATION 1 Be sure roller catches inside warmer cavity are in the open position Install drawer assemblies in drawer slides 2 Place appropriate one drawer insert pan into each warmer drawer If used place one Humitrol rack into each drawer pan Fig 7 Roll Warmer Drawer Pan Installation HUMITROL RACK DRAWER I...

Page 16: ...ear the end of its service life The appliance will continue to operate for a period of time after the light glows to allow continued operation through a peak period However the indicated filters must be replaced within a reasonably short time period or they will clog and shut down electrical power to the cooking appliance The ventilator blower will continue to run 5 When the red SERVICE REQUIRED l...

Page 17: ... now ready to use USING THE GRIDDLE 1 Turn the temperature control knob to the desired temperature The indicator light will glow while the griddle is heating When the indicator light first goes out the griddle is ready to use 2 For standard griddles keep the griddle surface clean and well oiled during use Scrape cooking waste into the grease tray frequently during use Occasionally brush or spray a...

Page 18: ...steam vents where water droplets may form e Check the water level in the pan periodically and add water when necessary f Set the front air vent between fully closed and half open Actual setting will depend upon the type and amount of product stored in the drawer the temperature setting and the frequency with which the drawer is opened 2 Moist heat with pans a This Wells warmer is designed to accom...

Page 19: ...keys when display reads F C Within 3 seconds press UP arrow or DOWN arrow key until desired indicator ºF or ºC glows The new value will lock into memory 3 seconds after last keystroke DRAWER WARMER OPERATION when provided OPERATION continued ITEM DESCRIPTION 1 PROCESS Key Press to view actual temperature of cavity 2 4 Character LED Display Normally shows SETPOINT temperature 3 ºF or ºC Indicator G...

Page 20: ...ol panel or wiring Do not splash or pour water on in or over any controls control panel or wiring IMPORTANT DO NOT use steel wool or metal implements to clean drawers or cabinet surfaces VENTILATOR SECTION CLEANING INSTRUCTIONS PREPARATION Disconnect appliance from electric power Allow to cool before cleaning FREQUENCY Weekly TOOLS Warm water and a mild detergent Soft clean cloth or sponge Bristle...

Page 21: ...ly TOOLS Warm water and a mild detergent Soft clean cloth or sponge Plastic scouring pad plastic scraper CLEANING Disconnect appliance from electric power Allow to cool before cleaning Spiral Hotplate Elements Raise elements Remove and empty drip pans Drip pans and element supports may be washed in a sink or dishwasher Allow to air dry and reinstall Scrape burned on food debris from element using ...

Page 22: ...Dry the griddle surface thoroughly h Season the cooking surface after each cleaning using the instructions on page 10 3 At least once each day the grease trough must be thoroughly cleaned Using a scraper remove all grease and food waste from the grease trough and into the grease drawer 4 After scraping all cooking waste from grease trough into grease drawer take the grease drawer to kitchen cleani...

Page 23: ... end of the cabinet mounted rails Press down on both left and right latch c Pull drawer away from warmer 2 Clean drawers drawer pans Humitrol Racks and or insets with warm water and mild detergent Rinse all components thoroughly with clear water Dry all components prior to reinstalling them in warmer 3 Sweep crumbs and other debris from warmer cavity 4 Clean the outside of the unit by wiping with ...

Page 24: ...ement fasteners for tightness 5 Check all cabinet drawer catches for tightness and operation Lubricate Be certain roller is out before attempting to install drawer 6 Check thermostat thermobulb and capillary tube for condition Thermobulb must be securely mounted in the appropriate holder Arrange repairs for damaged thermobulb or capillary tube 7 Check drawer faceplate and handle fasteners for tigh...

Page 25: ...ervice Internal damage Contact Authorized Wells Service Agent for repairs Hotplate only will not heat Hotplate Temperature Control not set Set Hotplate Temperature Control to desired temperature Each hotplate is controlled individually Internal damage Contact Authorized Wells Service Agent for repairs Griddle only will not heat Griddle Temperature Control not set Set Griddle Temperature Control to...

Page 26: ...N AGENT TANK and FLEX HOSE must be hydrostatically tested and the FIRE EXTINGUISHING AGENT must be replaced in accordance with the maintenance schedule published in ANSUL R 102 SYSTEM STANDARD UL 300 LISTED b The FUSIBLE LINKS in plenum and damper must be REPLACED This maintenance to be performed by qualified Ansul service personnel only USE AND MAINTENANCE SHALL BE IN ACCORDANCE WITH THE STANDARD...

Page 27: ...M508 p n 2M 304456 Owners Manual WV 2HG 25 WELLS BLOOMFIELD LLC IL2144 ...

Page 28: ...E LOG MUST BE KEPT IN A PROTECTIVE COVER PERMANENTLY ATTACHED TOTHE APPLIANCE Log all repairs and recommendations on reverse side Any repairs other than replacement of factory authorized parts to the fire suppression plumbing system must be subject to hydrostatic pressure testing Log TEMP Log TEMP Log Mfg DATE Stamp Log Mfg DATE Stamp IL2610 Inspect fire suppression detectors all releasing devices...

Page 29: ...and com m on nam e s W t W t CAS No CAS No ACGIH TLV ACGIH TLV Acute Toxicity Data Acute Toxicity Data None Proprietary M ixture of O rganic and Inorganic Salts 48 0 50 0 Phosphoric A cid 0 2 7664 38 2 Yellow G reen Fluorescent Dye 0 011 518 47 8 O ral LD rat 50 6800 m g kg EDTA 0 65 64 02 8 Water Approx 50 0 7732 18 5 Boiling Point Percent Volatile by Volum e Solubility in Water Appearance and Od...

Page 30: ...om s occur If irritation persists seek m edical attention Dilute by drinking large quantities of water Respiratory Protection Specify Type N A N A N A Ventilation Local Exhaust M echanical G eneral Protective Gloves Rubber gloves for spill leak Eye Protection Chem ical goggles recom m ended during spill leak procedures Other Protective Clothing or Equipm ent Eye wash and safety showers are good sa...

Page 31: ...AUTHORIZED ANSUL SERVICE PERSONNEL Refer to Ansul part no 418078 05 R 102 Restaurant Fire Suppression System Design Installation Recharge and Maintenance ref MOUNTING BRACKET RELEASE MECHANISM R 102 ANSUL p n 79493 NOT SHOWN MICROSWITCH 2E 47273 TERM BLOCK 2E 33068 ref TANK 1 5 GAL ANSULEX ANSUL p n 429864 NOT SHOWN ANSULEX EXTINGUISHING AGENT 1 5 GAL ANSUL p n 79694 CARTRIDGE LT 20 R ANSUL ANSUL ...

Page 32: ... WV 2HG EXPLODED VIEW PARTS LIST 30 HOOD SECTION CABINET COMPONENTS IL2278a PL508 INTERNAL BRACKETS CABINET DOORS NON RW UNITS WV2HG Hood Section Cabinet Comonents RW UNITS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Sold by the Foot 18 ...

Page 33: ...LL STATION RED 6 5E 20804 CASTER ASSY 2FIX 2SWVL 7 WS 22649 KIT LEG REAR OPT WVF WVG 8 M3 304430 DOOR HINGE RIGHT AND LEFT 9 2R 302166 HANDLE DOOR SNAP IN 10 2R 46502 MAGNET DOOR 11 DD 504427 DOOR ASSY LF AND RT WV FG 12 2I 302580 FILTER BAFFLE 13 M3 302688 PREFILTER CAGE 14 2I 302579 FILTER PRE HOOD UNIVERSAL 15 M3 302775 FILTERPACK ASSY UNIV HOOD 16 1P 302749 TAPE SILICONE GRAY VCS SOLD BY THE F...

Page 34: ...C PORT C FRONT OF HOOD ELECTRICAL UPPER HOOD ELECTRICAL UNDER HOOD ELECTRICAL REAR OF LOWER CABINET 3 pl WV2HG Hood Section Electrical Vaccum Comonents 19 IL2279a 17 20 21 22 16 18 14 13 15 7 8 3 9 10 11 12 4 5 6 2 1 EXPLODED VIEW PARTS LIST 32 HOOD SECTION ELECTRICAL VACUUM COMPONENTS ...

Page 35: ...J 31157 LIGHT SIGNAL RED 10 2J 30516 LIGHT SIGNAL AMBER 11 2J 35697 PILOT LT GREEN 2502V 1 3W 12 2E 70395 SWITCH ROCKER 240V 20A 13 2E 33068 TERM BLOCK FLAME SENSOR 14 2E 34005 JUMPER FLAME SENSOR TERM 15 2E 43880 RLY 208 240 DPDT RW UNITS ONLY 16 2E 302789 CONTACTOR 50A 3PH 208 50A 3 PH 2E 306040 CONTACTOR 75A 3 POLE 75A 1 PH 17 2K 304420 STRAIN RELIEF 1 1 4NPT 18 M3 304438 CORD SET ASSY 6 4 NEMA...

Page 36: ...ners Manual WV 2HG EXPLODED VIEW PARTS LIST 34 COOKTOP SECTION CABINET ELECTRICAL COMPONENTS IL2280 PL508 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 WV2HG Cooktop Section Cabinet Electrical Comonents ...

Page 37: ... ADAPTER 8 2D 30293DT DRIP TRAY 9 WS 50293 ELEMENT ASSY KIT 240V 2600W 10 WS 51989 SHROUD GREASE DRAWER 11 2E 30562 SWITCH INFINTE 240V 12 2J 30516 LIGHT SIGNAL AMBER 13 2K 31040 BUSHING 7 8 OD 14 2R 30583 KNOB ASSY FRONT HOTPLATE FRONT 2R 30584 KNOB ASSY REAR HOTPLATE REAR 15 WS 501774 GREASE CAN ASSY 16 G7 Z12047 PANEL FRONT GREASE DR 17 2R 38668 HANDLE GREASE DRAWER GRIDDLE 18 2R 30259 KNOB CON...

Page 38: ...G Drawer Warmer Section Cabinet Electrical Comonents IL2281a part of 18 WS 65923 set includes left and right WS 67096 heavy duty drawer assy complete 1 2 5 4 3 13 12 11 10 6 7 7 18 16 15 10 26 24 22 23 21 25 20 20 19 8 17 DRAWER WARMER SECTION CABINET ELECTRICAL COMPONENTS ...

Page 39: ... 32 HEX MS SS 9 10 2P 30483 BRNG RLLR TRK R116 11 2C 49395 RIVET POP 1 8X 265 SS 12 C8 32112 HANDLE RW DRAWER SRW320 13 WS 51796 KNOB SQUARE ROLL WARMER 14 2T 44475 THERMOMETER RW 2IN DIAL OPTIONAL TERMOMETER 15 WS 65923 REPR KIT DRW STOP W SPRING 16 C8 35683 SHEILD BULB RWS 17 C8 35677 ANGLE SUPPORT ELEM RWS 18 2C 30471 DRAWER STRIKE AND CATCH 19 2N 30482UL ELEM 240V 450W 240V 2N 30519UL ELEM 120...

Page 40: ...M508 p n 2M 304456 Owners Manual WV 2HG WIRING DIAGRAM 38 HOOD SECTION from p n 2M 305991 Rev A ...

Page 41: ...M508 p n 2M 304456 Owners Manual WV 2HG WIRING DIAGRAM 39 COOKTOP SECTION from p n 2M 305991 Rev A ...

Page 42: ...M508 p n 2M 304456 Owners Manual WV 2HG WIRING DIAGRAM 40 DRAWER WARMER SECTION RWT STYLE DRAWER WARMER SECTION RW STYLE WIRING DIAGRAM RWT 26 from p n 307532 Rev ...

Page 43: ...information available if calling for service RESTAURANT _____________________________ LOCATION _____________ INSTALLATION DATE ________________________ TECHNICIAN ___________ SERVICE COMPANY ________________________________________________ ADDRESS ___________________________ STATE ______ ZIP__________ TELEPHONE NUMBER _____ _____ _________ EQUIPMENT MODEL NO _______________ EQUIPMENT SERIAL NO ___...

Page 44: ...WELLS BLOOMFIELD LLC 10 Sunnen Dr St Louis MO 63143 telephone 314 678 6314 fax 314 781 2714 www wellsbloomfield com ...

Reviews: