background image

M212  p/n 2M-Z17213  OpM  WB1C & WB2C- W

affle Baker

INSTALLATION

4

UNPACKING & INSPECTION

Carefully remove the appliance from the carton. Remove all protective 

plastic film, packing materials and accessories from the appliance before 

connecting performing any installation procedure.
Carefully read all instructions in this manual and the Installation Instruction 

Sheet packed with the appliance before starting any installation.

Read and understand all labels and diagrams attached to the appliance.
Carefully account for all components and accessories before discarding 

packing materials. Store all accessories in a convenient place for later use.

COMPONENTS

1 or 2 ea.  

DRIP TRAY(S)

1 or 2 ea.  

HANDLE(S)

4 ea.  

ADJUSTABLE FEET

SETUP

Lightly lubricate threaded boss of upper grid using vegetable oil. Thread 

handle onto boss, making sure that they are fully seated. Handles are not 

removable once installed.

Setup the appliance only on a firm, level, non-combustible surface. Verify 

local codes for requirements. Concrete, tile, terrazzo or metal surfaces are 

recommended.
Install the provided adjustable feet, one on each corner of the appliance, 

in the holes provided. Verify that the unit sits firmly ON ALL FOUR FEET. 

Adjust as required to level the appliance.  All four feet must be adjusted to 

firmly contact the countertop in order to prevent tipping.

ELECTRICAL INSTALLATION

Refer to the nameplate. Verify the electrical service power. Voltage and 

phase must match the nameplate specifications. Connecting the waffle 

baker to the wrong voltage can severely damage the unit or cause 

noticeably decreased performance. 

IMPORTANT:

 Damage due to being connected to the wrong voltage is NOT 

covered by warranty.

SEASONING THE GRIDS

Lightly spray commercial waffle baker spray on both upper and lower grid.

Carefully close the upper grid. Turn the power switch ON, then allow the 

waffle baker to pre-heat for at least 20 minutes.

Using the handle, lift the upper grid and lightly re-coat both upper and lower 

grid. Lower the upper grid.
The appliance is now ready for use.

NOTE: 

DO NOT discard 

the carton or other packing 

materials until you have 

inspected the appliance for 

hidden damage and tested it 

for proper operation.

Refer to SHIPPING 

DAMAGE CLAIM 

PROCEDURE on the inside 

front cover of this manual.

CAUTION: RISK 

OF DAMAGE

DO NOT connect or 

energize this appliance until 

all installation instructions 

are read and followed. 

Damage to the appliance will 

result if these instructions 

are not followed.

CAUTION: 

ELECTRICAL 

SHOCK 

HAZARD

The ground prong of the 

power cord is part of a 

system designed to protect 

you from electric shock in 

the event of internal damage 

to the appliance.
NEVER CUT OFF THE 

GROUND PRONG (large 

round prong).  NEVER 

TWIST A PRONG TO 

FIT AN EXISTING 

RECEPTACLE.
Contact a licensed 

electrician to install an 

electrical receptacle 

appropriate to the voltage 

and amperage requirements 

of the waffle baker.

IMPORTANT: 

Damage due to being 

connected to the wrong 

voltage or phase is NOT

covered by warranty.

Summary of Contents for WB1C Series

Page 1: ...appliance Additional manuals are available from your WELLS DEALER THIS MANUAL MUST BE READ AND UNDERSTOOD BY ALL PERSONS USING OR INSTALLING THIS APPLIANCE Contact your WELLS DEALER if you have any q...

Page 2: ...note of loss or damage is signed by the delivery person 2 FILE CLAIM FOR DAMAGE IMMEDIATELY Regardless of the extent of the damage 3 CONCEALED LOSS OR DAMAGE if damage is unnoticed until the merchand...

Page 3: ...ion and consistent maintenance of this appliance will ensure that it gives you the very best performance and a long economical service life This manual contains information and instructions for the ve...

Page 4: ...ERATURE ON Start Stop HEAT TIME TEMPERATURE ON Start Stop UPPER GRID RAISED POSITION UPPER GRID LOWERED POSITION POWER SWITCH RIGHT SIDE POWER SWITCH LEFT SIDE LOWER GRID HANDLE RIGHT SIDE CONTROLS LE...

Page 5: ...t direct water jet or steam jet at this appliance or at any control panel or wiring Do not splash or pour water on in or over any controls control panel or wiring Exposed surfaces of this appliance ca...

Page 6: ...rical service power Voltage and phase must match the nameplate specifications Connecting the waffle baker to the wrong voltage can severely damage the unit or cause noticeably decreased performance IM...

Page 7: ...ature Use a soft bristle brush to lightly brush and clean cooking debris from the grids between waffles Reseason grids every 3 4 waffles to guard against waffles sticking This interval may be extended...

Page 8: ...her cooking debris can accumulate PREPARATION Unplug appliance from electric power Allow appliance to cool completely FREQUENCY Daily TOOLS Plastic Scouring Pad Soft Bristled Fiber Brush Mild Detergen...

Page 9: ...ack residue using a fiber brush Wipe down the grid surfaces carefully and thoroughly with water so that no carbon cleaning solution remains on the grids IMPORTANT Make certain water and cleaner are no...

Page 10: ...e SETTING THE TIME If necessary the factory pre set timer can be adjusted to satisfy individual preferences To Increase Time Press hold the UP button then press the Start Stop button the amount you wi...

Page 11: ...WB1C 120V 9 MODEL WB1C SINGLE WAFFLE BAKER CANTILEVER SK2634 01 10 13 5 15P PLUG BLACK WHITE GREEN TEMP TERMINAL TRANSFORMER SWITCH BLOCK PROBE 7 7 E3 E4 E1 E2 E8 E7 10VAC RTD A B E E C D D C j UPPER...

Page 12: ...10 16 13 REV WB1E SINGLE STD WAFFLE BAKER ELECTRONIC CONTROLS 208 240V 220 240V POWER CORD BLACK WHITE GREEN TEMP TERMINAL SWITCH BLOCK PROBE 7 7 E3 E4 E1 E2 E8 E7 10VAC RTD A B E E L D D K J UPPER HE...

Page 13: ...ANTILEVER 5 15P PLUG BLACK WHITE GREEN TEMP TERMINAL TRANSFORMER SWITCH BLOCK PROBE 7 7 E3 E4 E1 E2 E8 E7 10VAC RTD A B E E C D D C UPPER HEATING ELEMENT LOWER HEATING ELEMENT H J J TEMP PROBE 7 7 E3...

Page 14: ...SK2670 Rev A 3 17 14 Model WB1C Electronic Waffle Baker 1 5 6 7 8 9 10 11 12 18 19 20 10 9 8 25 1 26 24 27 30 37 38 39 26 40 36 35 34 33 32 31 29 9 28 7 21 2 22 23 24 13 14 41 15 16 17 2 3 4 EXPLODED...

Page 15: ...9 2C 31715 10 SCREW 8 32X5 16 PH RD HD WB1C 20 WB2C 10 2C 1825 8 WASHER 8 EXT STL NP WB1C 16 WASHER 8 EXT STL NP WB2C 11 B8 WL0359 1 ASM WELD UPR GRID MTG BRT WB1C 2 WB2C 12 2F 38917 1 GRID TOP CAST A...

Page 16: ...08 07 0004 6 SPACER ROUND NYLON WB1C 12 WB2C 33 B8 Z16898 1 TIMER TEMP CONTRL WB1C 2C WB1C 2 WB2C 34 2K Z1971 6 SPACER 257X 75X 25 NYLON WB1C 12 WB2C 35 2E 35127 1 SWITCH ROCK PLAS BEZEL W WB1C 2 WB2C...

Page 17: ...A WB2C WB2C 120V B8 Z16901 WIRE ASSY A WB1C WB1C 120V NI B8 Z16902 1 WIRE ASSY B WB1C WB1C 120V NI B8 Z16903 1 WIRE ASSY C WB1C 2C WB1C 120V 2 WB2C 120V NI B8 Z16904 1 WIRE ASSY D WB1C 2C WB1C 2 WB2C...

Page 18: ...M212 p n 2M Z17213 OpM WB1C WB2C Waffle Baker NOTES 16...

Page 19: ...NUMBER _____ _____ _________ EQUIPMENT MODEL NO _____________EQUIPMENT SERIAL NO _______________ VOLTAGE check one 208 240 DESCRIPTION PART NO PARTS SERVICE IMPORTANT Use only factory authorized servi...

Page 20: ...WELLS MANUFACTURING 10 Sunnen Dr St Louis MO 63143 telephone 314 678 6314 fax 314 781 2714 www wellsbloomfield com...