background image

INSTALLATION 

NOTE:

  DO NOT discard 

the carton or other packing 
materials until you have 
inspected the appliance for 
hidden damage and tested it 
for proper operation. 
Refer to 

SHIPPING DAMAGE 

CLAIM PROCEDURE 

on the 

inside front cover of this 
manual. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Fig. 2  Set the Wellsloks 

 

IMPORTANT: 

Water damage caused by 
failure to seat Wellsloks or 
failure to install gasket or to 
seal flange to counter is NOT 
covered by warranty 
 
 

UNPACKING & INSPECTION 
 

Carefully remove the appliance from the carton. Remove all  
protective plastic film, packing materials and accessories from the 
appliance before connecting electrical power or otherwise performing 
any installation procedure. 
 
Carefully read all instructions in this manual and the 

Installation 

Instruction Sheet

 packed with the appliance before starting any 

installation. 
 
Read and understand all labels and diagrams attached to the 
appliance. 
 
Carefully account for all components and accessories before 
discarding packing materials. Store all accessories in a convenient 
place for later use. 
 
 
 
 
 
 
 
 
 

PREPARATION 
 

Carefully read the 

Installation Instruction Sheet

 packed with the 

appliance for cutout dimensions and restrictions.  
 
For both  wood and non-combustible (i.e. metal) installation, do not 
install closer than 4-1/2” to front wall unless the control unit is placed 
beneath the warmer unit, in which case clearance to front wall may  
be 1”.  Also, do not install closer than 1” to back wall, 2” to side walls, 
or 6-3/4” to surface below unit. 
 
Supplied gasket must be installed under the mounting flange, and the 
Wellsloks turned out to seal the appliance and control unit to the 
counter. 
 
Apply a thin bead of food-grade silicone sealant where the flange 
meets the counter. 
 
 

024 

 306391

  

 OpM

anual 

for
 Retherma

liz

er HS

W
-6DAF  

Summary of Contents for HSW6DAF

Page 1: ...person responsible for TRAINING OPERATORS of this appliance Additional manuals are available from your WELLS DEALER THIS MANUAL MUST BE READ AND UNDERSTOOD BY ALL PERSONS USING OR INSTALLING THIS APP...

Page 2: ...damage is noted on the freight bill or express receipt and that the note of loss or damage is signed by the delivery person 2 FILE CLAIM FOR DAMAGE IMMEDIATELY Regardless of the extent of the damage 3...

Page 3: ...appliance Proper installation professional operation and consistent maintenance of this equipment will ensure that it gives you the very best performance and a long economical service life This manual...

Page 4: ...l for Rethermalizer HSW 6DAF W ELLS PERFORATED BASE PLATE WATER FILL SPOUT WATER LEVEL SENSOR HEATING ELEMENT TEMPERATURE SENSING BULB WELLSLOKS BACK FLOW PREVENTER WATER FILL TUBE HEATING INDICATOR T...

Page 5: ...instructions must be read and understood by all persons using or installing this appliance Cleanliness of this appliance is essential to good sanitation Read and follow all included cleaning instruct...

Page 6: ...iance before starting any installation Read and understand all labels and diagrams attached to the appliance Carefully account for all components and accessories before discarding packing materials St...

Page 7: ...TE Some jurisdictions may require an approved air gap device in the drain It is the responsibility of the plumbing installer to determine such requirement to provide and properly install the required...

Page 8: ...o the pan This will cause condensation on the inside of the shrouds Damage caused by condensation is NOT covered by warranty DO NOT use metal implements steel wool or caustic or abrasive cleansers to...

Page 9: ...temperature sensing probe to avoid damaging the capillary tube 3 Rinse rethermalizer thoroughly with a vinegar and water solution to neutralize all detergent cleanser residue Rinse with clear water 4...

Page 10: ...vers accumulated scale 2 Heat water to maximum temperature 190 F or higher 3 Pour contents of one package of commercial delime cleaner into each warmer pan Stir to dissolve cleaner Turn heat control O...

Page 11: ...el probe with Wells Lime Scale Cleaner Internal damage Contact your Authorized Wells Service Agency for repairs Rethermalizer trips circuit breaker Tank leaking or other internal damage Contact your A...

Page 12: ...06391 OpManual for Rethermalizer HSW 6DAF Model HSW6DAF PASTA RETHERMALIZER CHILI S PL024 IL1763 Rev A 5 6 09 1 2 3 4 5 6 8 9 10 11 24 22 21 20 18 23 17 16 14 15 19 13 12 7 THERMOBULB ref INSULATION n...

Page 13: ...6X 2 FTG FLEX CON 90 X 1 2 MOD 10 2I Z12311 2 GASKET FIBER WASHER 11 2K 48198 1 ELBOW 3 8 X 90 DEG BRASS 12 2K 48197 1 NIPPLE 3 8 NPT X 2 BRASS 13 2V 47650 1 VALVE ANTISYPHON 3 8 14 2T 40509 1 THERMO...

Page 14: ......

Page 15: ...__________ EQUIPMENT SERIAL NO _______________ VOLTAGE check one 208 240 PARTS SERVICE 13 DESCRIPTION PART NO none available at this time IMPORTANT Use only factory authorized service parts For factor...

Page 16: ...Created for by WELLS BLOOMFIELD LLC 10 Sunnen Dr St Louis MO 63143 telephone 800 807 8054 fax 314 781 2714 www wells mfg com...

Reviews: