This appliance conforms to NSF Standard 4 for sanitation only if 
installed in accordance with the supplied 

Installation Instructions

 

PRECAUTIONS AND GENERAL INFORMATION 

AGENCY APPROVAL INFORMATION 

STD 4 

E6070 

E6070 

024 

 306391

  

 OpM

anual 

for

 Retherma

liz

er HS

W

-6DAF  

WARNING: 

SHOCK HAZARD 

 

All servicing requiring access 
to non-insulated electrical 
components must be        
performed by a factory       
authorized technician. 
DO NOT open any access 
panel which requires the use 
of tools.  Failure to 
follow this warning can 
result in severe electrical 
shock.

 

 

CAUTION: 

RISK OF 
DAMAGE 

 

DO NOT connect or energize 
this appliance until all        
installation instructions are 
read and followed.  Damage 
to the appliance may result if 
these instructions are not 
followed. 

 

 

CAUTION: 

HOT SURFACE 

 

Exposed surfaces can be hot 
to the touch and may cause 
burns. 

This appliance is intended for use in commercial establishments 
only. 

 
This appliance is intended to hold pre-heated food for human       
consumption.  No other use is recommended or authorized by the 
manufacturer or its agents.

 

 

Operators of this appliance must be familiar with the appliance use, 
limitations and associated restrictions.  Operating instructions must be 
read and understood by all persons using or installing this appliance.

 

 

Cleanliness of this appliance is essential to good sanitation.  Read and 
follow all included cleaning instructions and schedules to ensure the 
safety of the food product. 

 

Disconnect this appliance from electrical power before performing any 
maintenance or servicing. 

 

This appliance is not jet stream approved.  Do not direct water jet or 
steam jet at this appliance, or at any control panel or wiring.  Do not 
splash or pour water on, in or over any controls,  control panel or     
wiring.    

 
Exposed surfaces of this appliance can be hot to the touch and may 
cause burns. 

 
Do not operate this appliance if the control panel is damaged.  Call 
your Authorized Wells Service Agent for service.

 

 

The technical content of this manual, including any wiring diagrams, 
schematics, parts breakdown illustrations and/or adjustment 
procedures, is intended for use by qualified technical personnel. 

 

Any procedure which requires the use of tools must be performed by a 
qualified technician. 

 

This manual is considered to be a permanent part of the appliance.  
This manual and all supplied instructions, diagrams, schematics, parts 
breakdown illustrations, notices and labels must remain with the 
appliance if it is sold or moved to another location. 

 

This appliance is made in the USA.  Unless otherwise noted, this 
appliance has American sizes on all hardware.

 

Summary of Contents for HSW6DAF

Page 1: ...person responsible for TRAINING OPERATORS of this appliance Additional manuals are available from your WELLS DEALER THIS MANUAL MUST BE READ AND UNDERSTOOD BY ALL PERSONS USING OR INSTALLING THIS APP...

Page 2: ...damage is noted on the freight bill or express receipt and that the note of loss or damage is signed by the delivery person 2 FILE CLAIM FOR DAMAGE IMMEDIATELY Regardless of the extent of the damage 3...

Page 3: ...appliance Proper installation professional operation and consistent maintenance of this equipment will ensure that it gives you the very best performance and a long economical service life This manual...

Page 4: ...l for Rethermalizer HSW 6DAF W ELLS PERFORATED BASE PLATE WATER FILL SPOUT WATER LEVEL SENSOR HEATING ELEMENT TEMPERATURE SENSING BULB WELLSLOKS BACK FLOW PREVENTER WATER FILL TUBE HEATING INDICATOR T...

Page 5: ...instructions must be read and understood by all persons using or installing this appliance Cleanliness of this appliance is essential to good sanitation Read and follow all included cleaning instruct...

Page 6: ...iance before starting any installation Read and understand all labels and diagrams attached to the appliance Carefully account for all components and accessories before discarding packing materials St...

Page 7: ...TE Some jurisdictions may require an approved air gap device in the drain It is the responsibility of the plumbing installer to determine such requirement to provide and properly install the required...

Page 8: ...o the pan This will cause condensation on the inside of the shrouds Damage caused by condensation is NOT covered by warranty DO NOT use metal implements steel wool or caustic or abrasive cleansers to...

Page 9: ...temperature sensing probe to avoid damaging the capillary tube 3 Rinse rethermalizer thoroughly with a vinegar and water solution to neutralize all detergent cleanser residue Rinse with clear water 4...

Page 10: ...vers accumulated scale 2 Heat water to maximum temperature 190 F or higher 3 Pour contents of one package of commercial delime cleaner into each warmer pan Stir to dissolve cleaner Turn heat control O...

Page 11: ...el probe with Wells Lime Scale Cleaner Internal damage Contact your Authorized Wells Service Agency for repairs Rethermalizer trips circuit breaker Tank leaking or other internal damage Contact your A...

Page 12: ...06391 OpManual for Rethermalizer HSW 6DAF Model HSW6DAF PASTA RETHERMALIZER CHILI S PL024 IL1763 Rev A 5 6 09 1 2 3 4 5 6 8 9 10 11 24 22 21 20 18 23 17 16 14 15 19 13 12 7 THERMOBULB ref INSULATION n...

Page 13: ...6X 2 FTG FLEX CON 90 X 1 2 MOD 10 2I Z12311 2 GASKET FIBER WASHER 11 2K 48198 1 ELBOW 3 8 X 90 DEG BRASS 12 2K 48197 1 NIPPLE 3 8 NPT X 2 BRASS 13 2V 47650 1 VALVE ANTISYPHON 3 8 14 2T 40509 1 THERMO...

Page 14: ......

Page 15: ...__________ EQUIPMENT SERIAL NO _______________ VOLTAGE check one 208 240 PARTS SERVICE 13 DESCRIPTION PART NO none available at this time IMPORTANT Use only factory authorized service parts For factor...

Page 16: ...Created for by WELLS BLOOMFIELD LLC 10 Sunnen Dr St Louis MO 63143 telephone 800 807 8054 fax 314 781 2714 www wells mfg com...

Reviews: