WEEKLY CLEANING INSTRUCTIONS  

 

PREPARATIONS:  

 Remove any insets, pans and/or adapter tops. 

 

 

 

 

 

Drain or remove water from well if used for wet 

     operation. 

 

 

FREQUENCY:      

Weekly, or whenever lime or scale is seen              

 

 

 

 

 

accumulating on the sides of the warmer pans. 

 
TOOLS:           

Commercial Delime Cleaner 

     Plastic 

Scouring 

Pad 

 

     Clean 

Cloth 

or 

Sponge 

 

 
1.  Add water to pans until water is at normal operating level  
 

(1” - 1 1/2” deep) or covers accumulated scale. 

 
2.   Heat water to maximum temperature (190ºF or higher). 
 

 

3.   Pour contents of one package of commercial delime cleaner  
 

into each warmer pan.  Stir to dissolve cleaner. Turn heat    

 

control OFF.  Cover pans. 

   
4.   Allow solution to soak at least one hour, or overnight for heavy 
 scale 

buildup. 

         
5.   Drain hot water from pans.  Scrub with a plastic scouring pad.  
 

Rinse thoroughly with hot water, then dry. 

 
6.   Refill pans with hot tap water and resume operation. 
 
7.   Heavy scale buildup may require additional treatments. 
 
 
 
 

CAUTION: 

CHEMICAL BURN 
HAZARD 

 

Deilimng chemicals may be 
caustic.  Wear appropriate    
personal protective equipment. 
Follow cleaner manufacturer's 
instructions for safest use. 
 

Summary of Contents for HSW6DAF

Page 1: ...person responsible for TRAINING OPERATORS of this appliance Additional manuals are available from your WELLS DEALER THIS MANUAL MUST BE READ AND UNDERSTOOD BY ALL PERSONS USING OR INSTALLING THIS APP...

Page 2: ...damage is noted on the freight bill or express receipt and that the note of loss or damage is signed by the delivery person 2 FILE CLAIM FOR DAMAGE IMMEDIATELY Regardless of the extent of the damage 3...

Page 3: ...appliance Proper installation professional operation and consistent maintenance of this equipment will ensure that it gives you the very best performance and a long economical service life This manual...

Page 4: ...l for Rethermalizer HSW 6DAF W ELLS PERFORATED BASE PLATE WATER FILL SPOUT WATER LEVEL SENSOR HEATING ELEMENT TEMPERATURE SENSING BULB WELLSLOKS BACK FLOW PREVENTER WATER FILL TUBE HEATING INDICATOR T...

Page 5: ...instructions must be read and understood by all persons using or installing this appliance Cleanliness of this appliance is essential to good sanitation Read and follow all included cleaning instruct...

Page 6: ...iance before starting any installation Read and understand all labels and diagrams attached to the appliance Carefully account for all components and accessories before discarding packing materials St...

Page 7: ...TE Some jurisdictions may require an approved air gap device in the drain It is the responsibility of the plumbing installer to determine such requirement to provide and properly install the required...

Page 8: ...o the pan This will cause condensation on the inside of the shrouds Damage caused by condensation is NOT covered by warranty DO NOT use metal implements steel wool or caustic or abrasive cleansers to...

Page 9: ...temperature sensing probe to avoid damaging the capillary tube 3 Rinse rethermalizer thoroughly with a vinegar and water solution to neutralize all detergent cleanser residue Rinse with clear water 4...

Page 10: ...vers accumulated scale 2 Heat water to maximum temperature 190 F or higher 3 Pour contents of one package of commercial delime cleaner into each warmer pan Stir to dissolve cleaner Turn heat control O...

Page 11: ...el probe with Wells Lime Scale Cleaner Internal damage Contact your Authorized Wells Service Agency for repairs Rethermalizer trips circuit breaker Tank leaking or other internal damage Contact your A...

Page 12: ...06391 OpManual for Rethermalizer HSW 6DAF Model HSW6DAF PASTA RETHERMALIZER CHILI S PL024 IL1763 Rev A 5 6 09 1 2 3 4 5 6 8 9 10 11 24 22 21 20 18 23 17 16 14 15 19 13 12 7 THERMOBULB ref INSULATION n...

Page 13: ...6X 2 FTG FLEX CON 90 X 1 2 MOD 10 2I Z12311 2 GASKET FIBER WASHER 11 2K 48198 1 ELBOW 3 8 X 90 DEG BRASS 12 2K 48197 1 NIPPLE 3 8 NPT X 2 BRASS 13 2V 47650 1 VALVE ANTISYPHON 3 8 14 2T 40509 1 THERMO...

Page 14: ......

Page 15: ...__________ EQUIPMENT SERIAL NO _______________ VOLTAGE check one 208 240 PARTS SERVICE 13 DESCRIPTION PART NO none available at this time IMPORTANT Use only factory authorized service parts For factor...

Page 16: ...Created for by WELLS BLOOMFIELD LLC 10 Sunnen Dr St Louis MO 63143 telephone 800 807 8054 fax 314 781 2714 www wells mfg com...

Reviews: