background image

ENGLISH

12 

ENGLISH

FRANÇAIS

GAS ORIFICE CONVERSION CHART 

14 

CONVERSION CHART - GRIDDLE

 

NATURAL GAS 

ELEVATION 

LP / PROPANE 

SEA LEVEL - 2000’ 

KIT NO. 23154 

KIT NO. 23149 

2,000’ - 2,999’ 

KIT NO. 23155 

KIT NO. 23150  

3,000’ - 3,999’ 

KIT NO. 23156  

4,000’ - 4,999’ 

KIT NO. 23151  

5,000’ - 5,999’ 

6,000’ - 6,999’ 

KIT NO. 23152  

7,000’ - 7,999’ 

8,000’ - 8,999’ 

KIT NO. 23153  

9,000’ - 9,999’ 

ABOVE 10,000’ 

KIT NO. 23157  

GRAPHIQUE DE CONVERSION - GRILL PROFESSIONNEL 

GAZ NATUREL  

ELEVATION 

PROPANE / GPL 

NIVEAU DE LA MER - 2000’ (610M)  

KIT NO. 23154 

KIT NO. 23149 

2,000’ - 2,999’  (610M - 914M) 

KIT NO. 23155 

KIT NO. 23150  

3,000’ - 3,999’ (915M - 1219M) 

KIT NO. 23156  

4,000’ - 4,999’ (1220M - 1524M) 

KIT NO. 23151  

5,000’ - 5,999’ 1525M - 1829M) 

6,000’ - 6,999’ (1830M - 2133M 

KIT NO. 23152  

7,000’ - 7,999’ (2134M - 2438M) 

8,000’ - 8,999’ (2439M - 2743M) 

KIT NO. 23153  

9,000’ - 9,999’ (2744M - 3048M) 

AU-DESSUS DE 10,000’ (3049M) 

KIT NO. 23157  

GRAPHIQUE DE CONVERSION - LE CAPUCHON D'ORIFICE 

M

123   2M

-307735 

Owners M

anual for

 HDTG

-Series Heavy-Duty Ga

s G

riddle

s

 

Summary of Contents for HDTG-2430G

Page 1: ...ield com OWNERS MANUAL HEAVY DUTY GAS GRIDDLE w THERMOSTAT MODELS HDTG 2430G HDTG 3630G HDTG 4830G HDTG 6030G Includes INSTALLATION USE CARE EXPLODED VIEW PARTS LIST 123 p n 2M 307735 Rev D M123 14042...

Page 2: ...CLAIM FOR DAMAGE IMMEDIATELY Regardless of the extent of the damage 3 CONCEALED LOSS OR DAMAGE if damage is unnoticed until the merchandise is unpacked notify the transportation company or carrier imm...

Page 3: ...S 10 TROUBLESHOOTING SUGGESTIONS 12 PARTS SERVICE 13 CUSTOMER SERVICE DATA 13 ENGLISH FRAN AIS GAS CONVERSION CHART GRAPHIQUE DE CONVERSION 14 EXPLODED VIEW PARTS LIST LA VUE EXPLOSEE LES PARTIES ENUM...

Page 4: ...ADJUSTABLE LEG GREASE TRAY CONTROL VALVE COOKING SURFACE GREASE TROUGH GREASE CHUTE OPENING INTERIOR COMPONENTS BURNER ASSEMBLIES PILOT LIGHTS THERMOSTATIC CONTROL VALVE typical PILOT ADJUST EXHAUST...

Page 5: ...appliance if the smell of gas is present Turn off all gas supply valves and move to a remote location to call your Authorized Wells Service Agent for service The technical content of this manual incl...

Page 6: ...ction Sheet packed with the appliance before starting any installation Read and understand all labels and diagrams attached to the appliance Carefully account for all components and accessories before...

Page 7: ...riddle to the gas supply system must be black iron pipe or other material as approved by local ordinance for gas piping 2 Gas supply piping must be inside 3 4 diameter or greater 3 Use pipe sealant ma...

Page 8: ...gas pressure regulator It is the responsibility of the gas piping installer to identify the code requirement for a shut off valve Shut off valves moisture trap and all associated piping must be suppli...

Page 9: ...l knobs then remove the front panel Turn an individual burner on Loosen the locking screw on the shutter Turn the shutter to admit more or less air as required Adjust the air shutter until the flame i...

Page 10: ...ll near floor level because some gas is heavier than air and will settle to the floor For initial startup and any time the gas supply has been shut off it may take several minutes to light the pilot w...

Page 11: ...d e For new griddles repeat this procedure 2 3 times until the griddle has a slick clean surface OPERATION Inspect the unit for cleanliness before use Clean as necessary See Cleaning Instructions page...

Page 12: ...aned Using a scraper remove all grease and food waste from the grease trough by pushing it down the waste hole and into the grease tray 6 After scraping all cooking waste from grease trough into the g...

Page 13: ...low burners to air dry so that interior passages are completely free of water Examine burners to be sure the air shutters are in their proper position Reinstall burners with flame openings up The vent...

Page 14: ...nent Contact Authorized Wells Service Agency for repairs Portions of a burner won t light or have erratic flame Burner wet or flame opening s clogged Clean and dry burner Burner not hot enough Tempera...

Page 15: ...___ FUEL check one NATURAL GAS PROPANE LP ENGLISH DESCRIPTION PART NO LEGS ADJUSTABLE 4 METAL SET of 4 20563 PARTS SERVICE 13 IMPORTANT Use only factory authorized service parts and replacement filter...

Page 16: ...157 GRAPHIQUE DE CONVERSION GRILL PROFESSIONNEL GAZ NATUREL ELEVATION PROPANE GPL NIVEAU DE LA MER 2000 610M KIT NO 23154 KIT NO 23149 2 000 2 999 610M 914M KIT NO 23155 KIT NO 23150 3 000 3 999 915M...

Page 17: ...RULEUR PILOT ADJUST DUAL WS 506632 LE PILOTE AJUSTE DOUBLE PILOT ADJUST SINGLE 2K 39315 LE PILOTE AJUSTE SEUL PILOT STRAIGHT CUT TO LENGTH WS 507188 PILOTER DROIT LA COUPURE A LONGUEUR CONTROL KNOB CO...

Page 18: ...MPORTANT L acqu reur de ce mat riel doit afficher en pleine vue du public les instructions suivre en cas de d tection d une odeur de gaz par l utilisateur Cette information doit tre obtenue apr s cons...

Page 19: ...l contient l information n cessaire pour installer correctement l appareil et pour l utiliser et l entretenir de mani re ce qu il fonctionne avec des performances optimales INTRODUCTION SP CIFICATIONS...

Page 20: ...DS R GLABLES BAC POUR LA GRAISSE CONTROLER LE BOUTON SURFACE DE CUISSON PLATEAU POUR LA GRAISSE OUVERTURE DU CONDUIT D VACUATION DE LA GRAISSE CONDUIT D VACUATION DES GAZ ENSEMBLES DE BR LEURS CONTROL...

Page 21: ...re dans un lieu loign pour appeler un technicien d entretien agr par Wells La partie technique du pr sent manuel y compris tous les sch mas clat s illustrant les pi ces et ou les proc dures de r glage...

Page 22: ...incluse avec l appareil avant de commencer l installation Lire et assimiler la signification de toutes les tiquettes et sch mas fix s sur l appareil V rifier que tous les composants et accessoires so...

Page 23: ...ial pour les tuyauteries gaz sur tous les raccords de tuyauterie Appliquer le mastic en petite quantit uniquement sur les filetages m les Le mastic doit tre r sistant l action du gaz GPL 4 V rifier qu...

Page 24: ...de gaz Un robinet d arr t de gaz manuel peut tre exig par les codes locaux et son installation est fortement recommand e dans tous les cas Le robinet d arr t doit tre install entre la tuyauterie d ali...

Page 25: ...rs puis enlever le panneau avant Allumer l un des br leurs Desserrer la vis de blocage sur le volet Tourner le volet pour admettre plus ou moins d air le cas ch ant R gler le volet d a ration jusqu ce...

Page 26: ...Pour la mise en route initiale et chaque fois que l alimentation de gaz a t coup e il pourra falloir plusieurs minutes pour allumer la flamme de la veilleuse pendant que l air est purg de la tuyauteri...

Page 27: ...e op ration 2 3 fois jusqu ce que la surface du grill soit luisante et propre FONCTIONNEMENT DU GRILL Inspecter l unit pour v rifier sa propret avant usage Nettoyer le cas ch ant voir page 24 S assure...

Page 28: ...n grattoir enlever toute la graisse et tous les d chets de nourriture du bac graisse en les poussant travers le trou d vacuation jusqu au plateau graisse 6 Apr s avoir gratt tous les d chets de cuisso...

Page 29: ...eurs l air pour que les passages int rieurs soient totalement d pourvus d eau Examiner les br leurs pour v rifier la bonne position des volets d a ration Remettre les br leurs en place avec les trous...

Page 30: ...t Bouton de commande de temp rature br leur ou autre composant interne endommag Contacter le distributeur agr Wells pour effectuer les r parations Des parties de br leur ne s al lument pas ou leur fla...

Page 31: ...TAL __________ NUM RO DE T L PHONE _____ _____ _________ NUM RO DE MOD LE DE L QUIPEMENT ____________________________ NUM RO DE S RIE DE L QUIPEMENT ______________________________ COMBUSTIBLE L UN MAR...

Page 32: ...WELLS MANUFACTURING 10 Sunnen Dr St Louis MO 63143 telephone 314 678 6314 fax 314 781 2714 www wellsbloomfield com PRINTED IN CHINA...