10
Similar types of thermoplastic materials have widely
varying thermal behaviour. The molecular structure and
the additives used are dominant factors. It is therefore
necessary to determine temperature data by
experiment. The processing temperature (data sheets,
data books) is useful as a starting point.
Trouble Shooting
If the WST 82 heats unevenly or remains cold, the following
should be checked:
1. Temperature setting
2. Connection to control unit
3. The resistance at plug
Between pins 2 and 4 = approx. 22 Ohm
Between pins 1 and 2 = approx. 9 Ohm
Between pins 1 and 2 = approx. 7 Ohm
If other values are measured, the heater element is
defective.
7. Items supplied
WST 82 KIT1:
Thermal removal of insulation WST 82
T005 87 250 34
Brass wire brush
T005 87 257 42
Cutting knife set 23 mm
T005 87 257 22
Universal Knife 9 mm x 2 mm
T005 15 032 98
Safety rest
WST 82 KIT2:
Thermal removal of insulation WST 82
T005 87 250 34
Brass wire brush
T005 15 032 98
Safety rest
8. Accessories
T005 87 257 22
Universal Knife 9 mm x 2 mm
T005 87 257 29
Knife set AWG 12, 14, 24, 26
(2,0; 1,6; 0,51; 0,4 mm)
T005 87 257 32
Knife set AWG 14, 18, 22, 26
(1,6; 1,02; 0,64; 0,4 mm)
T005 87 257 42
Cutting knife set 23 mm
Subject to technical alterations and amendments!
See the updated operating instructions at
www.weller-tools.com.