30
Cooper Tools GmbH, Carl-Benz-Str. 2, 74354 Besigheim, P.O. Box 1351
Germany, Tel: (07143) 580-0, Fax: (07143) 580108
The individual program steps must be activated
manually
by pressing the
START
key. After the cooling time
has ended, the process must be ended manually by pressing the
START
key or
STOP
key.
The four times, as determined, are now in the temporary memory of the program location. The programming
unit will show the Status display.
The process times are saved by pressing the program key twice as described in Section 3.5,
Saving
and
Loading.
Note:
If the times determined with the teach-in mode are too long or if the target temperatures are not
obtained, the corresponding settings (Temp. of top heater, Temp. of bottom heater and Airflow) must
be gradually increased.
3.7
Special functions
The programming unit will show the
Status
display (it may be necessary to exit the active menu with the Exit
key).
Pressing the
Exit
key and
also
pressing the
PROGRAM
key will call up the special functions menu.
S E C I
A L -
F U N C T I
O N
M E N U E
>
O F F S E T
N O Z .
0 0 0 ° C
O F F S E T
P R E H .
0 0 0 ° C
S T A N D B Y
N O Z .
1 0 0 ° C
S T A N D B Y
P R E H .
O F F ° C
L O C K M O D E
M O D E
O
F A N S P E E D
1 0 0
%
° C /
° F -
D I
S P L A Y
° C
The functions are selected using the
arrow keys
∧
∨
.
To change a value, the value must be confirmed with
the
Select
key. The arrow
>
will jump to the value that is currently being set.
The value can be
changed
with the
arrow keys
∧
∨
.
Special Function
Menu
Setting special functions