the
display. The setback status is ended by pressing the
UP
or
DOWN
button. In the case of soldering work with very low
heat requirement, the reliability of the Setback function may
be impaired.
Change the setback time with the
UP
or
DOWN
button.
Switch to the previous menu item with
1
.
Switch to the next menu item with
I-II-III.
5.1.5 Window function
Restriction of the temperature range to a max. ±99°C
(± 180°F) beginning with a locked temperature (see 5.1.7).
The locked temperature thus represents the middle of the
settable temperature range.
Use the
UP/DOWN
buttons to change the window size.
Switch to the previous menu item with
1
.
Switch to the next menu item with
I-II-III
.
5.1.6 °F/°C Switch-over
Switching the temperature version from
°C
to
°F
and vice
versa.
Use the
UP/DOWN
buttons to switch between
°C
and
°F
.
Switch to the previous menu item with
1
.
Switch to the next menu item with
I-II-III.
37
5.1.2 Temperature switch-off Off time
When the soldering tool is not in use, the heating system of
the soldering tool is switched off when the Off time has elap-
sed. The temperature can be set from 0 – 999 minutes. With
a setting of
"0 min"
, the setback function is switched off.The
temperature switch-off is carried out independently of the
set setback function. The actual temperature is displayed
(flashing) and serves as a residual heat indication;
"OFF"
appears in the display. Below 50°C (150°F), a flashing dash
appears.
Change the off time with the
UP
or
DOWN
button.
Switch to the previous menu item with
1
.
Switch to the next menu item with
I-II-III
.
5.1.3 Temperature offset
The actual soldering tip temperature can be changed by
±40°C/±72°F by inputting a temperature offset.
Change the offset value with the
UP
or
DOWN
button.
Switch to the previous menu item with
1
.
Switch to the next menu item with
I-II-III
.
5.1.4 Setback time
If the soldering tool is not being used, the temperature is
decreased automatically to standby temperature (see 5.1.1)
after the specified setback time has elapsed. The setback
time, after which the soldering station switches to standby
mode, can be set from 0 – 99 minutes. With a setting of
"0 min"
, the setback function is switched off. With the "ON"
setting, the Setback function with swithing holder (optional)
is active (see Page 170). The setback status is indicated by
a flashing actual value display and
"STANDBY"
appears in
English
Summary of Contents for WD 1M
Page 8: ...WD 2 ...
Page 9: ...WD 2M ...
Page 179: ...170 Setback function ...
Page 180: ...171 USB interface ...
Page 181: ...172 Exploded Drawing WD 2 WD 2 ...
Page 182: ...173 Circuit Diagram WD 2 ...
Page 183: ...174 Exploded Drawing WD 2M WD 2M ...
Page 184: ...175 Circuit Diagram WD 2M ...