1-3. Safety 

Standards 

   Normes de sécurité 

Safety in Welding, Cutting, and Allied Processes, 

ANSI Standard Z49.1, from Global Engineering 
Documents (phone: 1-877-413-5184, website: 
www.global.ihs.com). 
 

 
 

Code for Safety in Welding and Cutting

, CSA 

Standard W117.2, from Canadian Standards 
Association, Standards Sales, 178 Rexdale 
Boulevard, Rexdale, Ontario, Canada M9W 1R3 
(phone: 800

463

6727 or in Toronto 

416

747

4044, website: 

www.csa

international.org). 

 

Safety in Welding, Cutting, and Allied Processes, 

ANSI Standard Z49.1, de Global Engineering 
Documents (téléphone : 1-877-413-5184, site 
Internet : www.global.ihs.com). 
 

 

 

Code for Safety in Welding and Cutting

, CSA 

Standard W117.2, de Canadian Standards 
Association, Standards Sales, 178 Rexdale 
Boulevard, Rexdale, Ontario, Canada M9W 1R3 
(téléphone : 800-463-6727 ou à Toronto 
416-747-4044, site Internet : 
www.csa-international.org).

 

1-4. EMF 

Information 

 EMF 

Information

 

 

Considerations About Welding And The Effects 
Of Low Frequency Electric And Magnetic Fields

 

Welding current, as it flows through welding 
cables, will cause electro- magnetic fields. There 
has been and still is some concern about such 
fields. However, after examining more than 500 
studies spanning 17 years of research, a special 
blue ribbon committee of the National Research 
Council concluded that: “The body of evidence, in 
the committee’s judgment, has not demonstrated 
that exposure to power- frequency electric and 
magnetic fields is a human-health hazard.” 
However, studies are still going forth and 
evidence continues to be examined. Until the 
final conclusions of the research are reached, 
you may wish to minimize your exposure to 
electromagnetic fields when welding or cutting.

 

To reduce magnetic fields in the workplace, use 
the following procedures:

 

1. Keep cables close together by twisting or 
taping them.

 

2. Arrange cables to one side and away from the 
operator.

 

3. Do not coil or drape cables around your body.

 

4. Keep welding power source and cables as far 
away from operator as practical.

 

5. Connect work clamp to work piece as close to 
the weld as possible.

 

About Pacemakers:   

Pacemaker wearers consult your doctor first. If 
cleared by your doctor, then following the above 
procedures is recommended 

Considérations sur le soudage et les effets de 
basse fréquence et des champs magnétiques et 
électriques. 

Le courant de soudage, pendant son passage dans 
les câbles de soudage, causera des champs 
électromagnétiques. Il y a eu et il y a encore un 
certain souci à propos de tels champs. Cependant, 
après avoir examine plus de 500 études qui ont été 
faites pendant une période de recherché de 17 ans, 
un comité spécial ruban bleu du National Research 
Council a conclu : « L’accumulation de preuves, 
suivant le jugement du comité, n’a pas démontré 
que l’exposition aux champs magnétiques et 
champs électriques à haute fréquence représente 
un risque à la santé humaine ». Toutefois, des 
études sont toujours en cours et les preuves 
continuent à être examinées. En attendant que les 
conclusions finales de la recherché soient établies, 
il vous serait souhaitable de réduire votre 
exposition aux champs électromagnétiques 
pendant le soudage ou le coupage. 

Pour réduire les champs magnétiques sur le poste 
de travail, appliquer les procédures suivantes : 

1. Maintenir les câbles ensemble en les tordant ou 

en les enveloppant. 

2. Disposer les câbles d’un côté et à distance de 
l’opérateur. 

3. Ne pas courber pas et ne pas entourer pas les 
câbles autour de votre corps. 

4. Garder le poste de soudage et les câbles le plus 
loin possible de vous. 

5. Connecter la pince sur la pièce aussi près que 
possible de la soudure. 

En ce qui concer ne les sti  mulateurs 
cardiaques 

Les porteurs de stimulateur cardiaque doivent 
consulter leur médecin avant de souder ou 
d’approcher des opérations de soudage. Si le 
médecin approuve, il est recommandé de suivre les 
procédures precedents

Summary of Contents for ThunderCut65

Page 1: ...lasma cutting Plasma gouging Plasma Arc Cutting Machine Date of purchase ________________ Machine Number ________________ Where purchased ________________ www weldking com THUNDERCUT 65 OWNER S MANUAL...

Page 2: ...responsibility 7 SECTION 2 INSTALLATIONS 8 2 1 ThunderCut 65 plasma cutting machine and gun specifications 8 2 2 Connection diagram 10 2 3 Install procedure 11 2 4 Electric service guide 12 SECTION 3...

Page 3: ...rendre garde et suivre lesinstructions aff rentes pour viter tout risque Les instructions enmati re de s curit indiqu es ci dessous ne constituent qu un sommaire des instructions de s curit plus compl...

Page 4: ...couper ou le sol y Ne pas se servir de source lectrique courant lectrique dans les zones humides dans les endroits confin s ou l o on risque de tomber y Se servir d une source lectrique courant lectr...

Page 5: ...s unit y Ne pas placer l appareil sur au dessus ou proximit de surfaces inflammables y Ne pas installer l appareil proximit de produits inflammables y Ne pas surcharger l installation lectrique s assu...

Page 6: ...ourner votre visage du d tendeur r gulateur lorsque vous ouvrez la soupape de la bouteille y Le couvercle du d tendeur doit toujours tre en place sauf lorsque la bouteille est utilis e ou qu elle est...

Page 7: ...ding to minimize the possibility of interference y Le rayonnement haute fr quence HF peut provoquer des interf rences avec les quipements de radio navigation et de communication les services de s curi...

Page 8: ...rrange cables to one side and away from the operator 3 Do not coil or drape cables around your body 4 Keep welding power source and cables as far away from operator as practical 5 Connect work clamp t...

Page 9: ...distorted or contaminated should be replaced immediately Should such repair or replacement become necessary WeldKing recommends that a telephone or written request for service advice be made to the Au...

Page 10: ...e V 90 108 Rated Duty cycle 60 Rated working current A 65 Gas Delay time s 2 15 Rated cutting thickness mm Mild steel 25 4 1 inch at 350mm min 14 IPM 12 7 1 2 inch at 1250mm min 50 IPM Severance 38mm...

Page 11: ...at 50A Cool style Air cooled Maximum Air pressure Bar 5 72psi Air consumption l min 150 Cable length M 6 20ft Connection Centre connection Detailed gun specification please see separate gun manual Tab...

Page 12: ...Page 10 2 2 Connection diagram Figure 2 1 Power cord Cutting torch S75 Earth clamp connect to work piece Connect to air supply...

Page 13: ...the anti rotation device by pressing it on proper hole C To disconnect torch also need press enclosed tool to the hole Finally remove the tool and continue to fasten the ring until hear clicking See...

Page 14: ...ODES AVERTISSEMENT LE RACCORDEMENT DE CETTE MACHINE DE SOUDAGE L ALIMENTATION DOIT TRE CONFORME AUX CODES D LECTRICIT PERTINENTS Input voltage V 208 230 Frequency Hz 60 60 Input Amperes at rated outpu...

Page 15: ...Page 13 SECTION 3 OPERATION CAUTION BEFORE OPERATING THIS MACHINE READ THE SAFETY SECTION OF THIS MANUAL THOROUGHLY 3 1 Front Back panel Layout Figure 3 1 Figure 3 1 5 6 7 8 2 1 3 4...

Page 16: ...lamp 3 Over heat protection indicator 4 Air Gauge filter 5 Output current adjust knob 6 Gas delay adjust Knob 7 Torch terminal 8 Earth lead terminal 9 Power switch 10 Fuse 11 Power cord 12 Compress ai...

Page 17: ...you to avoid any danger from sparks and hot metal Push the safety trigger at the side of the torch first then press the switch to start cutting The working lamp green will illuminate Does not fire the...

Page 18: ...in Mild steel 26 GA 0 5 25 638 16205 10 GA 3 4 40 151 3835 1 4 6 4 65 132 3353 3 8 10 65 63 1600 1 2 12 65 42 1067 5 8 16 65 31 787 3 4 19 65 22 559 Aluminum 1 32 0 8 25 610 15494 1 8 3 2 40 204 5182...

Page 19: ...lfunction poor contact Check contact situation Replace lamp Main switch malfunction Check switch replace if necessary 3 Electric leak at the case Power cord leak Insulate power cord Transformer contac...

Page 20: ...nect Control circuit board failure Check and repair the circiut board Poor contact at earth lead and gun cable Check and re connect Loose or poor connection with the main power supply link Check the c...

Page 21: ...hort circuit Check and replace Work excess the rated duty circle Use under rated duty circle Input voltage is too high Use proper voltage 11 Torch sputters and hisses The gas filter at the rear of the...

Page 22: ...f the cable connections are over heated Check if the cable is connected firmly and properly if it is broken and cause bad insulation Check the cover grounded properly Moisture in the torch can cause t...

Page 23: ...mable explosive materials or gases 5 2 3 Gas cylinder must be located at a safe and steady place to avoid injury others 5 2 4 Keep finger hair and clothing away from the rotating fan 5 2 5 The power s...

Page 24: ...Y08070002 Knob PN 21D Middle 1 5B Y01430013 Post flow time potentiometer WT118 2W 100K 1 6 Y07060003 Quick Receptacle 35 50 cm black small 1 7 Y07060010 Center connection FY 0022 1 8 Y21060001 Air gau...

Page 25: ...Page 23 Figure 7 1 1 2 3 4 5 6 7 8...

Page 26: ...Page 24 Figure 7 2 34 35 36 38 37...

Page 27: ...Page 25 S75 Plasma torch parts breakdown Figure 7 6...

Page 28: ...CV0026 GUIDE 3 CV0028 GUIDE SPRING 4 CV0033 CROWN SHIELD 5 CV0051 CUTTING GUIDE 6 CV0052 CIRCLE CUTTING GUIDE 7 CV0076 NOZZLE CAP 8 EA0223 O RING 9 FH0647 DIP TUBE 10 PC0114 NOZZLE 11 PD0114 10 TIP 1...

Page 29: ...Page 27 NOTES WELDKING THUNDERCUT65...

Page 30: ...sold or manufactured MALO WELDING PRODUCTS LTD WELDKING S PRODUCTS ARE FOR COMMERCIAL INDUSTRIAL USE AND PERSONS TRAINED AND EXPERIENCED IN THE USE AND MAINTENANCE OF WELDING PLASMA CUTTING EQUIPMENT...

Page 31: ...om to fill the warranty registration form Malo Welding Products Ltd will not distribute of disclose customer s private information to any third party and will not sent promotion material to the custom...

Page 32: ...MALO WELDING PRODUCTS LTD 3275 14th ave Unit A Markham Ontario Canada L3R 0H3 Tel 1 866 686 5088 Fax 1 866 686 5090 www malowelding com Printed October 7 2011...

Reviews: