User Manual
7
Neck Wire Inlet Guide
The neck guide will wear as the wire is fed through into the neck. To
maintain trouble free wire feeding periodically check and renew this
guide.
Liner Fitting
•
•
Remove the liner retaining nut from the gun plug body liner stem.
• Remove the old liner by pulling it out of the stem.
• Feed the new liner into the gun plug liner stem. Push up the torch until it hits the
guide in the torch handle. The liner should be visible through the inspection hole
of the guide.
•
retaining nut over the nipple.
•
To remove the guide;
• Remove the retaining screw using a hexagonal key. 2mm A/F.
• Lift the guide out of its location. Removing the feed rolls will make this easier.
• There is a renewable liner inner that can be replaced. Remove the gas seal O
ring and then withdraw the guide liner.
•
• Return the guide assembly into the drive unit location ensuring the O ring and
liner tube locate correctly. Secure using the retaining screw.
Neck
Guide
O Ring
Liner Inner
Guide Body
Screw