background image

11

 

Reassembling the pump.

 

1. Place the head assembly on the housing, observing the 
position of the air intake and exhaust ports.

 

 

Note: Make sure the diaphragm is seated properly 

in the well of the housing and head. Do not pinch the 
diaphragm or liner.

 

2. Insert the head screws and tighten each screw until it 
is snug in a criss cross pattern. Do not completely tighten 
the screws yet.

 

3. Using a torque wrench with the T-25 Hex attachment, 
tighten each head screw to 45 inch-pounds, in a criss 
cross pattern.

 Caution: To avoid property damage or personal injury, always 

try rotating the fan by HAND, prior to connecting the unit to the 
power source. Check for suction at the air inlet port by placing your 
fi nger over the port as you turn the fan. You should feel a slight 
suction with each rotation of the fan. If you don’t feel suction, or if 
you feel or hear a thump as you turn the fan, DO NOT CONNECT 
THE UNIT TO A POWER SOURCE; review the assembly 
procedure for possible error.

Section 6: SPECIFICATIONS

6.10  Specifi cation

Welch Model

2019B-01

2019C-02

Free air Displacement
CFM (L/min) @ 60Hz
CFM (L/min) @ 50Hz

1.3 (36)
1.1 (30)

1.3 (36)
1.1 (30)

Maximum Vacuum InHg

24

24

Ultimate Pressure Torr (mbar)

150 (200)

150 (200)

Maximum Continuous Pressure 
PSIG

18

18

Tubing needed, I.D., inches

1/4

1/4

Weight, Ibs (kg)

10.2 (4.6)

11.2 (5.1)

Cord

North American 115V Plug

European Schuko Plug

Motor H.P.

1/15

1/15

Motor Voltage & Frequency

115V, 60Hz, 1 Phase

230V, 50Hz, 1 Phase

Motor Amps

3.5

1.7

Overall Pump Dimensions 
L x W x H inches (cm)

8.75 x 5.0 x 8.75

(22.2 x 12.7 x 22.2)

10.4 x 5.0 x 8.75

(26.4 x 12.7 x 22.2)

Carton Dimensions
L x W x H inches (cm)

15.31 x 12.31 x 12.69

(38.9 x 31.3 x 32.2)

15.31 x 12.31 x 12.69

(38.9 x 31.3 x 32.2)

Shipping Weight, pounds (kg)

12.4 (5.6)

13.4 (6.1)

Summary of Contents for 2019B

Page 1: ...ng the pump See Section 3 15 CAUTION Do not pump liquids with the pump Pumping liquids will cause the pump to stop working Part No 642913 Printed in USA WELCH ILMVAC Welch Ilmvac 5621 W Howard Street...

Page 2: ...ons are found where failure to observe the instruction could result in damage to the equipment associated equipment and process These units conform to the SI International system of units of measureme...

Page 3: ...ump location 6 3 15 Discharge provisions 7 3 16 Electrical power 7 3 17 Traps 8 3 18 When to Use a liquid Trap 8 3 19 When to Use a cold Trap 8 3 20 The care of a liquid trap 8 3 21 The care of a cold...

Page 4: ...en the protector resets Always disconnect power source before servicing 1 15 Never drop or insert ngers or any other object into any openings 1 16 Do not operate this product where oxygen is being adm...

Page 5: ...re 1 41 Do not use this pump in or near explosive atmospheres or where aerosol spray products are being used 1 42 Do not use this product near ames WARNING Failure to observe the above safety precauti...

Page 6: ...ervice Support on www welchvacuum com 3 13 Pump Mounting Rubber feet are attached to the pump casing 3 14 Pump Location WARNING Don t operate this pump in an atmosphere containing ammable or explosive...

Page 7: ...Intake Hose barb tting 1 4 NPT x 3 8 ID hose 3 16 Electrical Power 3 16 1 Power Source Review Review the power source and the motor rating to be sure they agree in voltage phase and frequency Serious...

Page 8: ...he cold trap will come in contact with the surfaces of the trap and condense Commonly used refrigerants are liquid nitrogen or dry ice with alcohol slurry Dry ice provides suf cient cooling to freeze...

Page 9: ...he system and painting the suspected area with a thick soap solution Escaping air will produce soap bubbles 4 13 Operating Pressure Range Vacuum pumps are designed to be run from slightly below atmosp...

Page 10: ...emove head set head with screws aside for assembly 5 Remove four screws 2 from valve plate Remove valve plate and set aside for reassembly 6 Remove diaphragm liner and discard Reassembling the diaphra...

Page 11: ...n with each rotation of the fan If you don t feel suction or if you feel or hear a thump as you turn the fan DO NOT CONNECT THE UNIT TO A POWER SOURCE review the assembly procedure for possible error...

Page 12: ...Description 2019K 01 2019K 03 2500K 04 1 Diaphragm Buna N 1 1 2 Diaphragm liner PTFE 1 1 3 Diaphragm Hold Down Plate 1 4 Valve Plate Assembly 5 O Ring Gasket Head 1 6 Pump Head Assembly Includes item...

Page 13: ...d however short will be repaired under this warranty rather than replaced The warranty is effective for one year from the date of original purchase when 1 The warranty card has been completed and retu...

Page 14: ...L 60714 Phone 847 676 8800 Technical Support Fax 847 677 8606 E Mail gdwelchvacuum gardnerdenver com Web Page www welchvacuum com Copyright 1997 2007 Gardner Denver Welch Vacuum Technology Inc Welch i...

Reviews: