WELCH-ILMVAC 2019B Owner'S Manual Download Page 6

6

Section 3: INSTALLATION

3.10  Environmental Conditions
 

The Pump is rated for indoor use only. Maximum altitude 2000 meters. Operating temperature 
range 10

o

C to 40

o

C. Maximum relative humidity of 80% for temperatures up to 31

o

decreasing to 50% at 40

o

C. Rated for +/-10% of supply voltage. Pollution Degree 2, Installation       

Category II.

3.11  Introduction
 

This manual has been compiled not only for the care and maintenance of the Welch Vacuum 
pump now in your possession, but as a helpful reference and guide to prevent many problems 
which can occur if used improperly.

3.12  Unpacking
 

Carefully remove the Vacuum pump from the shipping case. Preserve all paperwork for 

future reference. If damage has occurred from shipment a claim must be fi led with the carrier 
immediately; preserve the shipping carton for inspection by the carrier. If you are required to 
communicate with your dealer or Welch Vacuum be sure to include your order numbers for 
quick identifi cation. Do not return the pump to the factory without obtaining returned goods 
authorization. *See “Service & Support” on www.welchvacuum.com.

3.13  Pump Mounting
 

Rubber feet are attached to the pump casing. 

3.14  Pump Location

 

WARNING

Don’t operate this pump in an atmosphere containing fl ammable or 

explosive gas

 

WARNING

The motor is thermally protected and will automatically restart 

unexpectedly when the overload device resets

 

The Vacuum pump should be located preferably in a clean, dry and well ventilated area. 
Please be sure not to block the ventilation ports located on the motor housing. The pump 
should be placed where the surrounding temperature remains between 10

o

C and 40

o

C (50

o

and 104

o

F). Always check to insure the location chosen is protected from direct or indirect 

moisture contact. The pump should be located as closely to its system in order to utilize it most 
effi ciently. 

3.15  Discharge Provisions
 

Vacuum Pump Model 2019 comes with two hose barbs, one Intake and one Exhaust. All 
hose barbs and muffl ers are supplied loose with the pump. The hose barb used on all models 
accepts 3/8” I.D. hose. By threading the hose barb in the exhaust port of the pump, a vent line 
can be attached which allows gases and vapors pumped through the pump to be piped from 
the work area into a hood. Vent lines will muffl e noise coming from the vacuum pump.

Summary of Contents for 2019B

Page 1: ...ng the pump See Section 3 15 CAUTION Do not pump liquids with the pump Pumping liquids will cause the pump to stop working Part No 642913 Printed in USA WELCH ILMVAC Welch Ilmvac 5621 W Howard Street...

Page 2: ...ons are found where failure to observe the instruction could result in damage to the equipment associated equipment and process These units conform to the SI International system of units of measureme...

Page 3: ...ump location 6 3 15 Discharge provisions 7 3 16 Electrical power 7 3 17 Traps 8 3 18 When to Use a liquid Trap 8 3 19 When to Use a cold Trap 8 3 20 The care of a liquid trap 8 3 21 The care of a cold...

Page 4: ...en the protector resets Always disconnect power source before servicing 1 15 Never drop or insert ngers or any other object into any openings 1 16 Do not operate this product where oxygen is being adm...

Page 5: ...re 1 41 Do not use this pump in or near explosive atmospheres or where aerosol spray products are being used 1 42 Do not use this product near ames WARNING Failure to observe the above safety precauti...

Page 6: ...ervice Support on www welchvacuum com 3 13 Pump Mounting Rubber feet are attached to the pump casing 3 14 Pump Location WARNING Don t operate this pump in an atmosphere containing ammable or explosive...

Page 7: ...Intake Hose barb tting 1 4 NPT x 3 8 ID hose 3 16 Electrical Power 3 16 1 Power Source Review Review the power source and the motor rating to be sure they agree in voltage phase and frequency Serious...

Page 8: ...he cold trap will come in contact with the surfaces of the trap and condense Commonly used refrigerants are liquid nitrogen or dry ice with alcohol slurry Dry ice provides suf cient cooling to freeze...

Page 9: ...he system and painting the suspected area with a thick soap solution Escaping air will produce soap bubbles 4 13 Operating Pressure Range Vacuum pumps are designed to be run from slightly below atmosp...

Page 10: ...emove head set head with screws aside for assembly 5 Remove four screws 2 from valve plate Remove valve plate and set aside for reassembly 6 Remove diaphragm liner and discard Reassembling the diaphra...

Page 11: ...n with each rotation of the fan If you don t feel suction or if you feel or hear a thump as you turn the fan DO NOT CONNECT THE UNIT TO A POWER SOURCE review the assembly procedure for possible error...

Page 12: ...Description 2019K 01 2019K 03 2500K 04 1 Diaphragm Buna N 1 1 2 Diaphragm liner PTFE 1 1 3 Diaphragm Hold Down Plate 1 4 Valve Plate Assembly 5 O Ring Gasket Head 1 6 Pump Head Assembly Includes item...

Page 13: ...d however short will be repaired under this warranty rather than replaced The warranty is effective for one year from the date of original purchase when 1 The warranty card has been completed and retu...

Page 14: ...L 60714 Phone 847 676 8800 Technical Support Fax 847 677 8606 E Mail gdwelchvacuum gardnerdenver com Web Page www welchvacuum com Copyright 1997 2007 Gardner Denver Welch Vacuum Technology Inc Welch i...

Reviews: