52
Step 18
Mix a solution of sanitizer and warm water.
Solution Type
Water
Mixed With
Sanitizer
6 gal. (23 l)
4 oz (120 ml) sanitizer
part number 9405653
Step 19
Use 1/2 of the sanitizer/water solution to
sanitize all removed components. Use a cloth or sponge to
liberally apply the solution to all surfaces of the removed
parts or soak the removed parts in the sanitizer/water
solution. Do not rinse parts after sanitizing.
Step 20
Use 1/2 of the sanitizer/water solution to
sanitize all foodzone surfaces of the ice machine and bin.
Use a cloth or sponge to liberally apply the solution. When
sanitizing, pay particular attention to the following areas:
• Evaporator plastic parts - including top, bottom and
sides
• Bin bottom, sides and top
Do not rinse the sanitized areas.
Step 21
Replace all removed components.
Step 22
Reapply power and water to the ice machine
and place the toggle switch in the ICE position.
Summary of Contents for Manitowoc NEO UDP0080A
Page 2: ......
Page 18: ...18 Part Number STH098 06 19 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 74: ...74 Part Number STH098 06 19 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 166: ...166 Part Number STH098 06 19 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 176: ...176 Part Number STH098 06 19 ELECTRONIC CONTROL BOARD UDP0080 1 2 3 4 5 6 7 8 9 10...
Page 179: ......