Ice Thickness Float Switch:
A. The light must be off in the down position.
B. The light must be on in the up position.
If the control board light does not respond to the float
proceed with step 1 below.
1. Disconnect power to the ice machine, pull the wire
connector for the float switch through the bulkhead
and disconnect.
2. Attach an ohm meter lead to each float switch wire.
3. Place the float in the down position - The float switch
must be closed.
4. Place the float in the up position - The float switch
must be open.
FLOAT CLOSED
FLOAT OPEN
NOTE: Make adjustments with the ice machine in the off
position. Making adjustments during the freeze cycle may
produce an initial sheet of ice that is thicker than future
cycles.
Float
Float Up
Float Down
Ice Thickness Float
OL
< 1 Ohm
Harvest Float
OL
< 1 Ohm