32
Part Number STH047 Rev01 10/18
D.
Remove the Ice Thickness Probe
• Compress the side of the ice thickness probe
near the top hinge pin and remove it from
the bracket.
COMPRESS SIDES OF ICE
THICKNESS PROBE
ICE
THICKNESS
PROBE
SV1138A
Ice Thickness Probe Removal
NOTE: At this point, the ice thickness probe can easily be
cleaned. If complete removal is desired, follow the ice
thickness probe wire to the bulkhead grommet (exit point)
in the back wall. Pop the bulkhead grommet out of the
back wall by inserting fingernails or a flat object between
the back wall and the grommet and prying forward.
Pull the bulkhead grommet and wire forward until the
connector is accessible, then disconnect the wire lead from
the connector.
Ice Thickness Probe Cleaning
• Mix a solution of ice machine cleaner and water
(2 ounces of cleaner to 16 ounces of water) in a
container.
• Soak the ice thickness probe a minimum of 10
minutes.
Clean all ice thickness probe surfaces and verify the ice
thickness probe cavity is clean. Rinse thoroughly with clean
water, then dry completely. Incomplete rinsing and drying
of the ice thickness probe can cause premature harvest.
Summary of Contents for Koolaire KD0270A
Page 2: ......
Page 16: ...16 Part Number STH047 Rev01 10 18 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 44: ...44 Part Number STH047 Rev01 10 18 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 52: ...52 Part Number STH047 Rev01 10 18 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 92: ...92 Part Number STH047 Rev01 10 18 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 120: ...120 Part Number STH047 Rev01 10 18 THIS PAGE INTENTIONALLY LEFT BLANK...
Page 135: ......