Part Number STH047 Rev01 10/18 21
Electrical Specifications
AIR-COOLED ICE MACHINE
Ice Machine
Voltage Phase
Cycle
Max. Fuse/
Circuit
Breaker
Total
Amps
KF150
115/60/1
15 amp
7.4
K170
115/1/60
15 amp
7.0
208/1/60
15 amp
3.5
230/1/50
15 amp
4.0
KF250
115/60/1
15 amp
11.8
K270
115/1/60
15 amp
10.7
208-230/1/60
15 amp
5.2
230/1/50
15 amp
5.2
n
Warning
All wiring must conform to local, state and national
codes.
n
Warning
The ice machine must be grounded in accordance with
national and local electrical code.
WATER-COOLED ICE MACHINES
Ice Machine
Voltage
Phase Cycle
Max. Fuse/
Circuit
Breaker
Total
Amps
K170
115/1/60
15 amp
6.3
208/1/60
15 amp
3.6
230/1/50
15 amp
4.0
K270
115/1/60
15 amp
9.9
208-230/1/60
15 amp
4.7
230/1/50
15 amp
4.7