100
Part Number STH047 Rev01 10/18
ICE THICKNESS CHECK
The ice thickness probe is factory-set to maintain the ice
bridge thickness at 1/8" (3.2 mm).
NOTE: Make sure the water curtain is in place when
performing this check. It prevents water from splashing out
of the water trough.
1. Inspect the bridge connecting the cubes. It should be
about 1/8" (3.2 mm) thick.
2. If adjustment is necessary, turn the ice thickness
probe adjustment screw clockwise to increase bridge
thickness, or counterclockwise to decrease bridge
thickness.
NOTE: Turning the adjustment 1/3 of a turn will change the
ice thickness about 1/16" (1.5 mm).
NOTE:
ADJUSTING
SCREW
SV3114
1/8" ICE BRIDGE
THICKNESS
SV3113
Ice Thickness Check
Make sure the ice thickness probe wire and the bracket do
not restrict movement of the probe.