Electronic Control Card TS004E
Commissioning
8.3.2 Terminal 6
Error: Position overtraveled
The level at this output is HIGH if the rotary indexing table/rotary indexing ring has overtraveled the
locked position.
8.3.3 Terminal 7
Error: Motor overload (movement timeout)
The level at this output is HIGH if the rotary indexing table/rotary indexing ring has not reached the
inductive sensor approximately 10 seconds after the start signal.
8.3.4 Terminal 8
General error
This output indicates that an error is pending. This also includes the errors at outputs 6 and 7.
Acknowledge the error with a LOW signal at the input
2
.
8.3.5 Terminal 9
Start permissible
The level is set to HIGH as soon as a new start is permissible.
8.3.6 Terminal 10
Rotary indexing table/rotary indexing ring in position
This output signals that the rotary indexing table/rotary indexing ring is in a valid position. The rotary
indexing table/rotary indexing ring is equipped with a position cam. The inductive sensor detects this
position cam and the signal is available at this output.
If the level at this output is HIGH, processing may start because the output flange no longer moves.
The motor of the rotary indexing table/rotary indexing ring continues to run for the duration of the
adjusted stop delay in order to reach the optimum start position for the next cycle.
If the level of this output signal changes to LOW, processing must be immediately stopped because the
output flange has left its position.
8.3.7 Terminal C
Motor contactor CW (forward)
Output 24 V/2 A for motor contactor and/or coupling coil with holding brake/coupling combination.
8.3.8 Terminal D
Brake
Output 24 V/2 A for direct connection of the motor holding brake.
8.3.9 Terminal E
Motor contactor CCW (reverse)
Output 24 V/2 A for motor contactor direction of rotation left.
User manual_082018_1.0_en