Electronic Control Card TS004E
Wiring
7
Wiring
7.1
Block diagram
1
Electronic control card TS004E
7
Terminal F
2
24 V inputs and outputs
8
Terminal D
3
3 x 400 V
9
Motor cable
4
Rotary indexing table/rotary indexing ring TC/TR
10
Emergency Stop
5
Terminal C
11
Holding brake
6
Electronic contactor
12
Inductive sensor
7.2
Motor cable
Downstream of the motor protection switch, the motor cable is switched by means of an electronic
contactor (solid state relay). The contacts of the Emergency Stop contactors must be installed between
the electronic contactor and the motor.
Refer to the information on the nameplate of the motor for rating the motor protection switch.
There are three versions of the electrical contactor,
One direction of rotation (motor power 0 ... 3 kW) (ES0480E-0000-0003-00)
Two directions of rotation (motor power 0 ... 0.75
kW)
(ES0480W-0000-0003-00)
Two directions of rotation (motor power > 0.75
kW)
(ES0480W-0000-0004-00)
User manual_082018_1.0_en
15 / 29