This allows to change the input source to e.g. Album-Player or
TV-Player etc. The same applies to the output port.
Tapping on an output port allows to mute / unmute the outputs
individually. MAN301 devices which have the internal D/A Con-
verter section not installed, show the „Analog Output“ entry as
disabled, i.e. the white dot is not in the bright state.
Note, the synchronization source settings can be di
ff
erent de-
pending on whether the „Player“ mode or the „Preamp“ mode or
the „Airplay“ mode is selected.
The default settings are as follows, in most cases these do not
need to be changed:
„Player“
mode: „Internal“ Synchronization, „Transparent“ Rate
Mode.
„Preamp“
mode: „S/PDIF (RCA)“ Synchronization (this is the
default input selected), „Fixed Rate“ Rate Mode (this can not be
changed due to the MAN301‘s hardware architecture).
„Airplay“
mode: „Internal“ Synchronization, „Transparent“ Rate
Mode.
Hints to connect external D/A Converters:
D/A CONVERTER TYPE
CONNECT VIA
Weiss DAC202
FireWire (select the Weiss DAC202
device as described above). Note, there
is a special DAC202 Firmware required
if connected via FireWire to the
MAN301 (see our website, downloads
page)
Weiss DAC202U
USB (select the Weiss DAC202 device as
described above)
Weiss DAC202 or DAC202U
or DAC2 or Minerva or
Medea or Medea+ or DAC1
Can also be connected via
AES/EBU or S/PDIF.
Weiss DAC2 or Minerva
Firewire (select the Weiss Minerva
device as described above)
Weiss DAC1 or Medea or
Medea+ with Firewire option
Firewire (select the Weiss INT202 device
as described above)
Weiss INT202 or INT203
Connecting these interfaces does not
make much sense, as the MAN301 has
them built in
93