Installation and operating instruction
Oil condensing boiler WTC-OB 18-B
3 Product description
83311002 1/2018-03 La
14-132
3.4 Technical data
3.4.1 Approval data
Method of installation
B
23
, B
33
, C
13
(1
, C
33
, C
53
, C
63
(2
, C
93
DIN CERTCO
3R279/...
VKF
22349
(1
France and Belgium only
(2
Not for Belgium
Basic standards
EN 267: 2011
EN 303-1: 2003
EN 303-2: 2003
EN 15034: 2007
EN 15035: 2007
Additional standards, see EU conformity certifica-
tion.
3.4.2 Electrical data
Mains voltage / mains frequency
230 V/50 Hz
Consumption
max 350 W
Power consumption without circulation pump
max 140 W
Power consumption standby
4 W
Internal appliance fuse
T6.3H, IEC 127-2/5
Fuse
max 16 A
Type of protection
IP 42D
3.4.3 Ambient conditions
Temperature in operation
+3 … +30 °C
Temperature during transport / storage
-10 … +60 °C
relative humidity
max 80 %, no dew point
3.4.4 Fuels
Fuel oil EL low-sulphur (max 50 mg/kg sulphur)
to DIN 51603-1 or similar national standards,
fuel oil EL A Bio 10 low-sulphur (max 50 mg/kg sulphur)
to DIN 51603-6 or similar national standards.
Addition of ash-forming additives is prohibited.