36
6
Display /Enter
Range
Factory
Note
pre-setting
☞
No external sensor
Normal temperature setpoint
Setback temperature
connected to B1
(– – – = Standby operation)
–
60°C
Limit value adjustable
Max. flow temperature
by Parameter P30, P31
heating engineer level
Room temperature setpoint
15° C – 35° C
22°C
☞
External sensor
(– – – = Standby operation)
connected to B1
Setback temperature setpoint
8° C
☞
No external sensor
(– – – = Standby operation)
–
30°C
connected to B1
Normal temp. setpoint
Setback room temperature setpoint
10° C
☞
External sensor
(– – – = Standby operation)
–
15°C
connected B1
Room temp. setpoint
S = Summer operation
S
W
☞
No external sensor
W= Winter operation
W
connected to B1
Current /
Change-over
☞
External sensor
external temp.
temperature
10° C – 30° C
20°C
connected to B1
Summer/Winter
DHW setpoint
30°C – 65°C
50°C
☞
Version -W
(– – – = DHW operation off)
(B3 connected)
Chimney sweep operation
Min. rating
☞
Ch. 10.3
variable ratings
–
– – –
☞
Ch. 5.5.2
setting
Max. rating
CODE input
Entry into heating
0 – 254
– – –
☞
Ch. 6.3.1
engineer level
6.2.2 Setting mode
Setting of setpoints and display of other system values.
Procedure:
•
The symbol line is displayed by turning the dial knob.
•
By turning the dial knob again, the selection cursor
can be placed under the relevant symbol.
If the selection cursor is moved beyond the left or
right positions, the display mode is shown.
The display mode also appears, if the enter key has
not been used for 20 seconds.
•
By pressing the enter key, the relevant symbol is
activated and the value set is flashing in the display.
The other symbols are faded out.
•
The value can be changed by turning the dial knob.
•
The value is confirmed by pressing the enter key and
the selection is exited. All symbols of the symbol line
are displayed again.
1
1
1
1
1
If the WTC is controlled remotely (via N1 see Ch.
4.6.4) or if an external controller (WCM-FB and/or
WCM-EM) is connected, the menu points are faded
out as the settings are carried out on the controllers.
If communication fails the symbols for emergency
operation are faded in.