Installation and operating instruction
Gas burner WG10…/0-D ZM-LN
9 Servicing
83300902 1/2019-02 La
68-112
9.4 Set mixing head
Observe notes on servicing [ch. 9.1].
The distance between diffuser and flame tube front edge S1 can not be measured
with the burner mounted. This is only possible indirectly with the mixing head re-
moved, with dimension Lx.
Dimension Lx changes according to the combustion head extension used.
Remove mixing head [ch. 9.3].
Turn setting screw
1
until it is flush with the nozzle assembly cover
(dimension X = 0 mm).
Check dimension Lx.
If the value measured deviates from dimension Lx:
Undo screws
2
.
Adjust flame tube
3
until dimension Lx has been reached.
Re-tighten screws
2
.
If the screws
2
have been loosened:
Check position of electrodes and gas orifices
4
.
Lx = 2
78 mm
Lx
S1 = 10 mm
X
45,5 mm
~ 4
5°
2
3
1
4