Installation and operating instruction
Gas burner WG10…/0-D ZM-LN
4 Installation
83300902 1/2019-02 La
24-112
4.2.1 Rotate burner by 180° (optional)
Mount operating panel
1
on the opposite side of the housing.
Mount fixing bracket
3
on the opposite side of the housing.
Rotate burner flange
2
180° and mount with flange gasket.
Rotate burner 180° and fit screws
4
to burner flange.
The aperture between combustion head and refractory should be filled with
flame-proof, resilient insulating material (do not make solid).
Check setting of electrodes [ch. 9.5].
Fit mixing head [ch. 9.3].
3
4
1
2