BUILT-IN SIDE BURNER INSTALLATION
This Side Burner is designed for
NON-COMBUSTIBLE
enclosures only, and must be installed and serviced by a
qualified installer to local codes. Use this manual in conjunction with your main manual to properly assemble
your built-in grill. Refer to the main manual for operating, cleaning, and maintenance instructions.
OPENING SIZES
MUST BE MINIMUM 4 1/2” (11 cm) DEEP
GAS ACCESS NEEDED AT FRONT RIGHT CORNER UNDER VALVE
1. Fit the side burner frame overtop of the opening, space equally around all sides. The frame must be
attached to the opening to prevent any future movement. (fasteners not included)
2. Ensure that there is at least 5 sq inches (32 cm
2
) of opening in the bottom of the cut out, for combustion air.
3. A flexible metal connector is included to simplify the installation of the side burner. Connect this connector
to the 3/8” flared elbow on the end of the side burner valve. Connect the other end of the connector to the
gas piping. Ensure the connector does not pass through a wall, floor, ceiling or partition, and is protected from
damage. Do not use a hose to connect the side burner. It must be connected with either rigid pipe, copper
tube or an approved flexible metal connector to the gas supply. The installation must comply with CAN B149.1
Natural Gas and Propane Installation code in Canada, or to the National Fuel Gas Code, ANSI Z223.1 in the
United States.
4. Set the side burner overtop of the frame. Leak test the entire installation before operating the unit.
N380-0022-RD
N051-0007
N160-0023
N415-0190 MAR 18.15
FRAME
SIZE
N357-0013
N500-0038
W255-0004
W445-0031
N720-0044
N720-0056
N555-0016
N725-0030 LPG
N725-0031 NAT
N255-0051
N335-0043-MO2
N485-0009
N305-0059
N500-0035K
N100-0037
N280-0045
N570-0076
N455-0060 LPG
N455-0061 NAT
15” (38 cm)
18” (46 cm)
12 3/4” (32 cm)
16 1/2” (42 cm)