background image

 

9

 

 

 

 

Project Management 

This page provides a way to restart the project of the cMT-SVR and restores it to its initial state without 
cycling power. 
[Restart Project] - Restarts cMT-SVR and restores it to its initial state. 

 

 

[Update Project]- Loads a project and recipes from the PC to the cMT-SVR. 

 

Summary of Contents for cMT-SVR-100

Page 1: ...User Manual cMT SVR 100 Startup Guide Weintek USA Inc www WeintekUSA com 425 488 1100 Rev SEP 8 2020...

Page 2: ...able of Contents 1 Network Wiring Diagram 3 2 Web Interface 4 3 OS Upgrade 14 4 cMT Viewer 15 5 Monitor Mode 23 6 cMT Viewer Limitations 27 7 cMT Objects Introduction 29 8 cMT SVR Gestures Operation 3...

Page 3: ...192 168 100 1 The IP addresses of LAN 1 and LAN 2 must be configured to different subnets cMT SVR LAN Ports cMT SVR HMI is equipped with two independent Ethernet ports which isolate the device network...

Page 4: ...nfiguration connect cMT SVR LAN1 to a router via an Ethernet cable Open a web browser IE Chrome or Firefox and enter the IP address of the cMT SVR For example enter 192 168 1 15 Select an identity and...

Page 5: ...anagement System Password Enhanced Security EasyAccess2 0 and Misc Network Set the IP addresses of Ethernet 1 LAN 1 port and Ethernet 2 LAN 2 port Choose Obtain IP address automatically or Use static...

Page 6: ...6 Ethernet2 LAN By default the IP address of Ethernet 2 is 192 168 100 1 Static IP Date Time Sync with host Synchronizes the HMI RTC with the PC RTC To confirm the action click on Save...

Page 7: ...n the LED on the cMT SVR will blink History This page is used to clear historical data recipe and database information stored in the internal memory of a cMT SVR Clear It is used to clear historical d...

Page 8: ...manual SMTP Enter your SMTP server port number user name and password Within Sender information enter your name and mail address so that the recipients can know where the email comes from Contacts Ad...

Page 9: ...way to restart the project of the cMT SVR and restores it to its initial state without cycling power Restart Project Restarts cMT SVR and restores it to its initial state Update Project Loads a proje...

Page 10: ...words of the three levels are 111111 User This level can operate cMT projects via cMT viewer Update project This level can load and retrieve the HMI project as well as retrieve historical data such as...

Page 11: ...security classes to prevent unauthorized operators from accessing objects that have the potential to cause damage or injury within your cMT SVR HMI project For more information refer to section 5 6 2...

Page 12: ...via the file created by Administrator Tools EasyAccess2 0 EasyAccess 2 0 is a tool that allows users to access and control a cMT SVR remotely from anywhere in the world cMT SVR 100 isNOTapre licensed...

Page 13: ...r to the EasyAccess2 0 user manual or EasyAccess2 0 help website https support ihmi net Misc FTP Client can modify USB SD data If enabled historical data stored in USB drive SD card can be modified vi...

Page 14: ...e update progress run HyperTerminal software on your PC and set the parameters to 115200 8 N 1 Connect your computer with the cMT SVR via COM1 RS 232 port 4 Insert the SD card to cMT SVR and reboot to...

Page 15: ...changed between the device and the cMT SVR Three client devices can remotely view and control the project of a cMT SVR simultaneously by default Supported Operating System Where to Download Compatibil...

Page 16: ...demonstration version 2 6 38 of cMT Viewer App is used 2 Edit Auto Play and Page Indicator icons are only present when Monitor Mode functionality is enabled in the Settings page Connect Menu Click th...

Page 17: ...17 After that the corresponding project will be loaded If you want to go back to Connect menu click on the Start Home button at the top left corner...

Page 18: ...aving the projects On History tab you can connect the recently accessed projects If cMT SVR HMIs are configured to DHCP the history records may not be usable anymore since the IP addresses are dynamic...

Page 19: ...to change the password of more settings at the bottom left corner Display datetime bar Determines if the time bar will be displayed at the top of cMT Viewer application Adjust cMT Viewer to windows si...

Page 20: ...se Password Protection functionalities click on more settings icon and log in with the password set on Change password The default password is 111111 There are more options available on the General ta...

Page 21: ...sword on Change password of this page Open Project The action to connect to the cMT SVR and load its project Close Project The action to close projects on cMT Viewer Server Settings The action to go t...

Page 22: ...hem click on Password Protect icon and enter the corresponding password The protected actions are accessible to users with knowledge of assigned password There is a countdown timer displayed as shown...

Page 23: ...atically so users will see the latest data without entering each cMT SVR project Click on the Auto Play button cMT Viewer will automatically go to the next page To pause Auto Play mode click the Pause...

Page 24: ...e Information button the names of each cMT SVR as well as their IP address will be displayed as shown below Tap the Gear Setup buttons to go to the web interface of each cMT SVR Click the Edit button...

Page 25: ...5x4 20 format AutoPlay Set up the time interval for Auto Play mode to go to the next page after the given time interval Note To show real time data for the project of a cMT SVR like below you must ena...

Page 26: ...xt object Bit Lamp object Word Lamp object Numeric Display object ASCII Display object Bar Graph object or Alarm Display object to show up to date data on this screen so you can see the data shown and...

Page 27: ...wser Media Player Video In USB Camera Video In IP Camera Video In Video Input analog Picture View PDF Reader VNC Viewer Selected features of Function Key Screen hardcopy Import user data User USB Secu...

Page 28: ...ximum capacity can be adjusted in Easybuilder pro software Here are the steps 1 Launch Easybuilder pro v6 01 01 or greater 2 Go to the Home tab System Parameters 3 Click on the Remote tab 4 Within cMT...

Page 29: ...to the value of a designated word register Set Word changes the value in a designated word register when the object is touched Multi state Switch is a combination of Word Lamp object and Set Word obj...

Page 30: ...ve word registers Other basic objects Option List displays a list of items that can be viewed and selected Once an item is selected the specified value will be written to a designated word register Sc...

Page 31: ...y word register Operators can open or close a pop up window by a designated word register at the predefined location Note The background transparency of Direct Window and Indirect Window is adjustable...

Page 32: ...32 Recipe Database Allows operators to view add update delete and use recipes...

Page 33: ...pplication for a boiler system Overview page Flow block displays the flow speed in a pipe or the speed in a transportation line Trending chart page Trend Display displays data in a chart The data must...

Page 34: ...lays latest alarm messages which are predefined in Event Log object Event detector and have met a trigger condition Event Display displays latest and historical alarm messages which are predefined in...

Page 35: ...log Trend Display History Data Display Event log Event Display Event Bar Chart Gantt Operation log Operation Log View Recipe Recipe View SQL SQL Query Result Viewer Others Option List Data Block Displ...

Page 36: ...sion is to provide quality customizable HMI solutions that meet the needs of all industrial automation requirements while maintaining customer satisfaction by providing on demand customer service WEIN...