background image

 

LED Indicators 

The front panel of Weidmüller’s IE-WL-AP-BR-CL-ABG contains several 
LED indicators. The function of each LED is described in the table below. 

LED

Color

State

Description

Front Panel LED Indicators (System)

On 

Power is being supplied from power 
input 1. 

PWR1

Green 

Off 

Power is 

not

 being supplied from 

power input 1. 

On 

Power is being supplied from power 
input 2. 

PWR2

Green 

Off 

Power is 

not

 being supplied from 

power input 2. 

On 

Power is being supplied via PoE. 

PoE

Amber 

Off Power 

is 

not

 being supplied via PoE. 

Blink 

(slow) 

Cannot get an IP address from the 
DHCP server (interval: 1 sec) 

Blink 

(fast) 

IP address conflict (interval: 0.5 sec) 

FAULT

Red 

Off 

Error condition does not exist. 

Green  Software Ready 

Green 

Blink 

The IE-WL-AP-BR-CL-ABG has been 
located by Weidmüller WLAN 
Administrator. (interval: 1sec) 

STATE

Green/Re

Red 

Booting error condition 

On 

SIGNAL 

(5 LEDs)

Green 

Off 

Signal level   
(for 

Client

 mode only) 

On 

IE-WL-AP-BR-CL-ABG functions in 

Bridge

 Mode. 

BRIDGE 

MODE

Green 

Off 

IE-WL-AP-BR-CL-ABG is not in 

Bridge

 

Mode. 

On 

IE-WL-AP-BR-CL-ABG functions in 

Client

 Mode. 

CLIENT 

MODE

Green 

Off 

IE-WL-AP-BR-CL-ABG is not in 

Client

 

Mode. 

On 

WLAN is in used 

WLAN

Amber 

Off WLAN 

is 

not

 in use 

 

TP Port LED Indicators (Port Interface)

On 

TP port’s 100Mbps link is 

active.

Blink  Data is being transmitted at 100 Mbps 

100M

Green 

Off 

TP port’s 100Mbps link is 

inactive

On 

TP port’s 10Mbps link is 

active

Blink  Data is being transmitted at 10 Mbps 

10M

Yellow 

Off 

TP port’s 10Mbps link is 

inactive

 
 
 
 
 
 

- 11 - 

Summary of Contents for IE-WL-AP-BR-CL-ABG-EU

Page 1: ...d manual and any further product information if available can be downloaded from the website http www weidmueller com downloads For manual select Print Media then goto Section Industrial Ethernet For...

Page 2: ...www weidmueller com downloads 1 Cable Holder with a Screw 2 Protective Caps Installation and Configuration Before installing the Wireless Device make sure that all items in the Package Checklist are i...

Page 3: ...change or the Save and Restart button to apply all changes Step 6 Test communications We will describe two test methods Use the first method if you are using only one IE WL AP BR CL ABG and use the se...

Page 4: ...hen press Enter key A Reply from IP address response means the communication was successful A Request timed out response means the communication failed In this case recheck the configuration to make s...

Page 5: ...take it out of the box If you need to reattach the DIN Rail attachment plate to the device make sure the stiff metal spring is situated towards the top as shown in the figures below STEP 1 Insert the...

Page 6: ...ould be less than 3 5 mm in diameter as shown in the figure at the right Do not screw the screws in all the way leave a space of about 2 mm to allow room for sliding the wall mount panel between the w...

Page 7: ...wire to determine which wires should be kept separate The rule of thumb is that wiring with similar electrical characteristics can be bundled together Keep input wiring and output wiring separate It...

Page 8: ...IE WL AP BR CL ABG has one relay output which consists of the two contacts of the terminal block on the IE WL AP BR CL ABG s top panel Refer to the previous section for detailed instructions on how t...

Page 9: ...e IE WL AP BR CL ABG and plugging in the LAN cable tighten the cable along the device and wall Communication Connections 10 100BaseT X Ethernet Port Connection The 10 100BaseT X ports located on the I...

Page 10: ...to see the numbers clearly 2 The pin numbers for both 8 pin and 10 pin RJ45 connectors and ports are typically not labeled on the connector or port Refer to the Pinout diagram above to see how RJ45 p...

Page 11: ...ULT Red Off Error condition does not exist Green Software Ready Green Blink The IE WL AP BR CL ABG has been located by Weidm ller WLAN Administrator interval 1sec STATE Green Re d Red Booting error co...

Page 12: ...ly Protocols ARP BOOTP DHCP STP RSTP IEEE 802 1D w TX Transmit Power for hardware revision 1 2 802 11b Typ 23 1 5 dBm 1 to 11 Mbps 802 11g Typ 20 1 5 dBm 6 to 24 Mbps Typ 19 1 5 dBm 36 Mbps Typ 18 1 5...

Page 13: ...15 WARRANTY 5 years Weidm ller gives a 5 year warranty on this product in accordance with the warranty terms as described in the general conditions of sale of the Weidm ller company which has sold the...

Page 14: ...NTION Use the antennas correctly The 2 4 GHz antennas are needed when the IE WL AP BR CL ABG operates in IEEE 802 11b g The 5 GHz antennas are needed for IEEE802 11a Make sure your antenna installatio...

Reviews: