RS-232 Connection 

The IE-WL-AP-BR-CL-ABG has one RS-232 (8-pin RJ45) console port 
located on the front panel. Use either an RJ45-to-DB9 or RJ45-to-DB25 
cable to connect the console port of the wireless device to your PC’s COM 
port. You may then use a console terminal program to access the 
IE-WL-AP-BR-CL-ABG for console configuration. 

Console Pinouts for 10-pin or 8-pin RJ45

10-Pin Description 8-Pin

1 -----   
2 DSR  1 
3 RTS  2 
4 GND  3 
5 TxD  4 
6 RxD  5 
7 DCD  6 
8 CTS  7 
9 DTR  8 

10 -----   

 

1

8

 

 

 

NOTE

1.

 

The pin numbers for male DB9 and DB25 connectors, and 
hole numbers for female DB9 and DB25 connectors are 
labeled on the connector. However, the numbers are 
typically quite small, so you may need to use a magnifying 
glass to see the numbers clearly. 

2.

 

The pin numbers for both 8-pin and 10-pin RJ45 connectors 
(and ports) are typically not labeled on the connector (or 
port). Refer to the Pinout diagram above to see how RJ45 
pins are numbered. 

ATEX Information 

II 3G

 

1.

 

DEMKO certification number: 11 ATEX 1105896X 

2.

 

Ambient range (-40°C 

 Tamb 

 75°C)   

3.

 

Certification string: Ex nA nL IIC T4 

4.

 

Standards covered ( EN60079-0:2006, EN60079-15:2005)   

5.

 

The conditions of safe usage: 
a.

 

The Ethernet Communication Devices are intended for mounting 
in an IP54 enclosure and used in an area of not more than 
pollution degree 2 as defined by IEC60664-1. 

b.

 

Conductors suitable for use in an ambient temperature greater 
than 93°C must be used for the Power Supply Terminal. 

c.

 

A 4 mm2 conductor must be used when connection to the 
external grounding screw is utilized. 

d.

 

Cables must be suitable for use in an ambient temperature 
greater than 93°C. 

- 10 - 

Summary of Contents for IE-WL-AP-BR-CL-ABG-EU

Page 1: ...d manual and any further product information if available can be downloaded from the website http www weidmueller com downloads For manual select Print Media then goto Section Industrial Ethernet For...

Page 2: ...www weidmueller com downloads 1 Cable Holder with a Screw 2 Protective Caps Installation and Configuration Before installing the Wireless Device make sure that all items in the Package Checklist are i...

Page 3: ...change or the Save and Restart button to apply all changes Step 6 Test communications We will describe two test methods Use the first method if you are using only one IE WL AP BR CL ABG and use the se...

Page 4: ...hen press Enter key A Reply from IP address response means the communication was successful A Request timed out response means the communication failed In this case recheck the configuration to make s...

Page 5: ...take it out of the box If you need to reattach the DIN Rail attachment plate to the device make sure the stiff metal spring is situated towards the top as shown in the figures below STEP 1 Insert the...

Page 6: ...ould be less than 3 5 mm in diameter as shown in the figure at the right Do not screw the screws in all the way leave a space of about 2 mm to allow room for sliding the wall mount panel between the w...

Page 7: ...wire to determine which wires should be kept separate The rule of thumb is that wiring with similar electrical characteristics can be bundled together Keep input wiring and output wiring separate It...

Page 8: ...IE WL AP BR CL ABG has one relay output which consists of the two contacts of the terminal block on the IE WL AP BR CL ABG s top panel Refer to the previous section for detailed instructions on how t...

Page 9: ...e IE WL AP BR CL ABG and plugging in the LAN cable tighten the cable along the device and wall Communication Connections 10 100BaseT X Ethernet Port Connection The 10 100BaseT X ports located on the I...

Page 10: ...to see the numbers clearly 2 The pin numbers for both 8 pin and 10 pin RJ45 connectors and ports are typically not labeled on the connector or port Refer to the Pinout diagram above to see how RJ45 p...

Page 11: ...ULT Red Off Error condition does not exist Green Software Ready Green Blink The IE WL AP BR CL ABG has been located by Weidm ller WLAN Administrator interval 1sec STATE Green Re d Red Booting error co...

Page 12: ...ly Protocols ARP BOOTP DHCP STP RSTP IEEE 802 1D w TX Transmit Power for hardware revision 1 2 802 11b Typ 23 1 5 dBm 1 to 11 Mbps 802 11g Typ 20 1 5 dBm 6 to 24 Mbps Typ 19 1 5 dBm 36 Mbps Typ 18 1 5...

Page 13: ...15 WARRANTY 5 years Weidm ller gives a 5 year warranty on this product in accordance with the warranty terms as described in the general conditions of sale of the Weidm ller company which has sold the...

Page 14: ...NTION Use the antennas correctly The 2 4 GHz antennas are needed when the IE WL AP BR CL ABG operates in IEEE 802 11b g The 5 GHz antennas are needed for IEEE802 11a Make sure your antenna installatio...

Reviews: